User Tools

Site Tools


switch-ctrl-en

Control

ContentObjectsSwitches


This option can be used to control an accessory to come in action 'by itself' with some timings.
An example of such an accessory is found in Plan-F: Module 9 "ZandKreek".
The timing is in normal time 1:1 seconds.1) (Model time, AKA Fast Clock has no effect.)



Activate

Activating the controller for this switch object.

Invert

Invert the commands for this switch object.

Auto mode

Only active in automatic mode.

Interval

The interval, in seconds, is the pause time between the end of an ON time and the begin of the next ON time.

Delay

The delay time, in seconds, between the begin end the end of the ON time.

Note: A controlled action is the overall time between the begin of "delay" (ON) and the end of "interval" (OFF).

Routes to lock

If this accessory affects the flow of running trains, it is very important to enter all routes involved to prevent accidents. This is comma separated list.
These routes will be locked before the ON action will take place. After the OFF action, all routes will be unlocked. Make sure the switch object ID is not equal to a locomotive ID!

Free blocks

The comma separated list of blocks must be free before the ON action.
If one or more blocks are not free the interval will be reset.

1)
With a deviation of + 1 sec.
switch-ctrl-en.txt · Last modified: 2023/10/19 12:29 by rjversluis