Marklin 6050/6051

ContentCommand StationsMarklin 6050/6051



Deprecated and no longer supported!

Because of the lack of a direction bit in this ancient protocol some features will probably not work in auto mode.

Cable configuration

Interface 6050/6051 to RS232

DIN-6 D-SUB-9 Label
1 3 Rx
4 2 Tx
5 8 CTS
3 5 Ground

Bridge on D-SUB-9 side pin: 4 - 6 - 1

Settings

General Command Station setup dialog:

Line settings

Baudrate

2400

Hardware Flow

CTS

Sensors

Number

Number of s88 units.

Version

If the version is set > 0 an extra sleep of 10ms is added after the CTS came active.
With version 2, the direction change will skip the preceding speed zero command. (14.357+)

Switch time

Time in ms to wait after the last switch command before a switch off command is send to prevent coil damaged.


Interface 6023

The 6023 interface must be switched to binary mode for using this protocol; Read section 6 on how to switch to binary mode.