 +======Marklin 6050/​6051======
 +[[:​english#​command_stations|{{ ​ :​interface.png}}]][[:​english|{{ ​ :​rocrail-logo-35.png}}]]
 +
 +[[english|Content]] -> [[english#​command_stations|Command Stations]] ->   ​**Marklin 6050/​6051** ​
 +   
 +
 +// \\ // \\
 +| Deprecated and no longer supported! |\\
 +
 +Because of the lack of a direction bit in this ancient protocol some features will probably not work in auto mode.\\
 + 
 +=====Cable configuration=====
 +Interface 6050/6051 to RS232
 +| **DIN-6** | **D-SUB-9** | Label |
 +| 1 | 3 | Rx |
 +| 4 | 2 | Tx |
 +| 5 | 8 | CTS |
 +| 3 | 5 | Ground |
 +
 +**Bridge** on D-SUB-9 side pin: **4 - 6 - 1**
 +
 +
 +=====Settings=====
 +General Command Station setup dialog:\\
 +{{:​p50-setup-en.png}}\\
 +
 +====Line settings====
 +===Baudrate===
 +2400\\
 +===Hardware Flow===
 +CTS\\
 +
 +====Sensors====
 +===Number===
 +Number of s88 units.
 +
 +====Version====
 +If the version is set > 0 an extra sleep of 10ms is added after the CTS came active.\\
 +With version 2, the direction change will skip the preceding speed zero command. (14.357+)\\
 +
 +====Switch time====
 +Time in ms to wait after the last switch command before a switch off command is send to prevent coil damaged.\\
 +
 + \\
 +=====Interface 6023=====
 +The 6023 interface must be switched to binary mode for using this protocol; Read section 6 on how to switch to binary mode.\\
 +  * {{:​marklin:​ma6023.pdf}}
 +
 + \\
  
6050-en.txt ยท Last modified: 2018/11/12 08:56 (external edit)