bidib-en
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
bidib-en [2018/12/02 16:12] – [Options] rjversluis | bidib-en [2023/10/29 09:57] (current) – [Options] rjversluis | ||
---|---|---|---|
Line 4: | Line 4: | ||
* [[: | * [[: | ||
* [[: | * [[: | ||
- | * [[http:// | + | [[:bidib-de|{{ icons:de.png|Deutsche Version}}]][[:bidib-en|{{ icons:uk.png|English |
- | [[:bidib-de|{{ icons:de.png|Deutsche | + | |
- | \\ | ||
- | [[http:// | ||
- | \\ | ||
- | ===== General information ===== | ||
- | {{ http:// | ||
- | BiDiB is a protocol which supports P&P with a high reliability communication level.\\ | ||
- | For more information: | ||
- | * http:// | ||
- | * [[http:// | ||
- | \\ | ||
- | //Rocrail is a BiDiB licensee.// | ||
\\ | \\ | ||
Line 35: | Line 23: | ||
\\ | \\ | ||
- | if sensor and input types at the same board exist the sensor range is 1 .. 128 and the input types are at 201 .. 328. | + | if sensor and input types at the same board exist the sensor range is 1 .. 128 and the input types are at 201 .. 328.\\ |
+ | |||
+ | **Tip:** Use the [[: | ||
===== Important Options===== | ===== Important Options===== | ||
Line 97: | Line 88: | ||
Host name or IP address.\\ | Host name or IP address.\\ | ||
===Port=== | ===Port=== | ||
- | TCP or UDP port.\\ | + | TCP port.\\ |
=== Baudrate === | === Baudrate === | ||
Line 109: | Line 100: | ||
=== Sub-Library === | === Sub-Library === | ||
* Serial (USB) | * Serial (USB) | ||
- | * [[https:// | + | * TCP: __**[[:mbus: |
- | | + | |
\\ | \\ | ||
==== Options ==== | ==== Options ==== | ||
- | {{: | + | {{: |
=== Secure ACK === | === Secure ACK === | ||
==Activate== | ==Activate== | ||
Line 122: | Line 112: | ||
The [[http:// | The [[http:// | ||
If Rocrail did not send an ACK with in this time frame the event will be resend by the sensor unit.\\ | If Rocrail did not send an ACK with in this time frame the event will be resend by the sensor unit.\\ | ||
- | |||
- | ===Echo commands=== | ||
- | Echo switch commands.\\ | ||
- | This can be used to synchronise multiple switches in Rocrail on the same address.\\ | ||
- | Note: __**[[: | ||
===Reset manually operated accessories=== | ===Reset manually operated accessories=== | ||
- | If a manually operated accessory is reported, as error, Rocrail will try to reset it back to its last known state.\\ | + | If a manually operated accessory is reported, as error, Rocrail will try to reset it back to its last known state. |
+ | \\ | ||
+ | === Report absent === | ||
+ | If this option is activated, it will be reported if a loco ID is no longer recognized by a RailCom detector. | ||
+ | \\ | ||
+ | === Query inputs === | ||
+ | Query also inputs at "Start of Day" | ||
+ | Only modules which are reporting number of inputs > 0 and using the Flat port model.\\ | ||
+ | |||
+ | ===Wizard=== | ||
+ | The TCP Port for the BiDiB-Wizard.\\ | ||
+ | If multiple masters are connected to this computer, every library must have its own unique port.\\ | ||
+ | \\ | ||
=== Watchdog === | === Watchdog === | ||
The **[[http:// | The **[[http:// | ||
Line 144: | Line 141: | ||
\\ | \\ | ||
- | \\ | ||
- | |||
- | ===== Hardware ===== | ||
- | |||
- | |||
- | ==== Documentation ==== | ||
- | **[[http:// | ||
- | |||
- | ^ Module ^ Description ^ Remark ^ | ||
- | | **GBMboost** | [[http:// | ||
- | | ** GBM16T** | [[http:// | ||
- | | **LightControl** | [[http:// | ||
- | | **MoBaLiSt** | [[http:// | ||
- | | **BiDiBOne** | [[http:// | ||
- | | **s88-Bridge*** | [[http:// | ||
- | |||
- | |||
- | \\ | ||
====Cable==== | ====Cable==== | ||
Line 190: | Line 169: | ||
Starting with firmware 2.1.4 the GBMBoost Master can be used as Programming Track.\\ | Starting with firmware 2.1.4 the GBMBoost Master can be used as Programming Track.\\ | ||
Before programming on the PT the PT-Mode must be set, see the __**[[: | Before programming on the PT the PT-Mode must be set, see the __**[[: | ||
- | \\ | ||
- | The GBM16T with Firmware 2.1.1 must be disconnected from the GBMBoost-Master or set into reset mode:\\ | ||
- | {{: | ||
\\ | \\ | ||
- | =====Compatibility===== | + | =====BiDiB Wizard===== |
- | * [[http:// | + | The Wizard can be connected to TCP port 62875 to configure nodes.\\ |
- | + | The [[:rocgui-menu-en# | |
- | \\ | + | |
- | + | ||
- | =====Virtual COM port (VCP) drivers===== | + | |
- | * [[http:// | + | |
- | + | ||
- | \\ | + | |
- | ===== Links ===== | + | |
- | * [[http:// | + | |
- | * [[http:// | + | |
- | * [[http:// | + | |
- | * [[http:// | + | |
- | + | ||
- | + | ||
- | \\ | + | |
- | + | ||
- | ===== Decoder Blacklist ===== | + | |
- | Here are decoders listed which are not conform the RailCom specs.\\ | + | |
- | + | ||
- | ====Tams==== | + | |
- | * LDG30/32 SW Version 2.1 -> http:// | + | |
- | + | ||
- | + | ||
- | + | ||
- | \\ | + | |
- | | **RailCom(r)** und **RailComPlus(r)** sind eingetragene Warenzeichen der Firma Lenz Elektronik GmbH in Hüttenbergstrasse 29, D-35398 Giessen | \\ |
bidib-en.1543763537.txt.gz · Last modified: 2018/12/02 16:12 by rjversluis