User Tools

Site Tools


bidib-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
bidib-en [2020/04/29 09:56] rjversluisbidib-en [2023/10/29 09:57] (current) – [Options] rjversluis
Line 7: Line 7:
  
  
- \\ 
-[[http://www.bidib.org/|{{http://www.bidib.org/pics/bidib_logo.png?150|BiDiB, ein universelles Steuerprotokoll für Modellbahnen}}]] \\ 
- 
-===== General information ===== 
-{{ http://www.opendcc.de/bidib/overview/bidib_system.png?400}} 
-BiDiB is a protocol which supports P&P with a high reliability communication level.\\ 
-For more information:  
-  * http://bidib.org/ 
-    * [[http://www.bidib.org/protokoll/bidib_general.html#T13|License DE]] [[http://www.bidib.org/protokoll/bidib_general_e.html#T13|EN]] 
- \\ 
-//Rocrail is a BiDiB licensee.//\\ 
  
  \\  \\
Line 34: Line 23:
  \\  \\
  
-if sensor and input types at the same board exist the sensor range is 1 .. 128 and the input types are at 201 .. 328.+if sensor and input types at the same board exist the sensor range is 1 .. 128 and the input types are at 201 .. 328.\\ 
 + 
 +**Tip:** Use the [[:sensormon-en|Sensor Monitor]] to find the right address.\\ 
  
 ===== Important Options===== ===== Important Options=====
Line 113: Line 105:
  
 ==== Options ==== ==== Options ====
-{{:bidib:bidib-setup-options-en.png}}\\+{{:bidib:bidib-setup-options-en.png?600}}\\
 === Secure ACK === === Secure ACK ===
 ==Activate== ==Activate==
Line 126: Line 118:
 === Report absent === === Report absent ===
 If this option is activated, it will be reported if a loco ID is no longer recognized by a RailCom detector. If this option is activated, it will be reported if a loco ID is no longer recognized by a RailCom detector.
 +  \\
 +=== Query inputs ===
 +Query also inputs at "Start of Day".\\
 +Only modules which are reporting number of inputs > 0 and using the Flat port model.\\
 +
 +===Wizard===
 +The TCP Port for the BiDiB-Wizard.\\
 +If multiple masters are connected to this computer, every library must have its own unique port.\\
 +
   \\   \\
 === Watchdog === === Watchdog ===
Line 168: Line 169:
 Starting with firmware 2.1.4 the GBMBoost Master can be used as Programming Track.\\ Starting with firmware 2.1.4 the GBMBoost Master can be used as Programming Track.\\
 Before programming on the PT the PT-Mode must be set, see the __**[[:pt-en#pt|PT Button]]**__ on the Programming Tab.\\  Before programming on the PT the PT-Mode must be set, see the __**[[:pt-en#pt|PT Button]]**__ on the Programming Tab.\\ 
- \\ 
-The GBM16T with Firmware 2.1.1 must be disconnected from the GBMBoost-Master or set into reset mode:\\ 
-{{:bidib:reset_gbm16t.png?400}}\\ 
  
  \\  \\
Line 176: Line 174:
 =====BiDiB Wizard===== =====BiDiB Wizard=====
 The Wizard can be connected to TCP port 62875 to configure nodes.\\ The Wizard can be connected to TCP port 62875 to configure nodes.\\
-The [[:rocgui-menu-en#enable_communication|Communication must be disabled]] before port 62875is serviced.\\+The [[:rocgui-menu-en#enable_communication|Communication must be disabled]] before port 62875 will be serviced.\\
  
bidib-en.1588147017.txt.gz · Last modified: 2020/04/29 09:56 by rjversluis