User Tools

Site Tools


dr5000-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
dr5000-en [2020/03/31 21:45] – [LocoNet LAN] smitt48dr5000-en [2024/03/16 11:12] (current) – [Z21] rjversluis
Line 7: Line 7:
 {{:dr5000:dr5000-backside.png?0x150}} {{:dr5000:dr5000-backside.png?0x150}}
  \\  \\
-|< >| 
-| **Use always the USB port in case of DR5000 configuration.** | 
  
-=====Setup USB===== +=====Setup LAN=====
-{{:dr5000:dr5000-usb.png}} +
- \\ +
-====Devices===== +
-Following serial devices are added for the DR5000: +
-^ Windows ^ Linux & RaspBerry Pi ^ Mac OS X ^ Protocol ^ Library ^ Sub-Library / Type ^ Baudrate ^ +
-| COM4 | /dev/ttyACM0 | /dev/tty.usbmodem1411 | LocoNet | loconet | __**[[:loconet-cs-en|LocoBuffer]]**__ |  57600 | +
-| COM6 | /dev/ttyACM1 | /dev/tty.usbmodem1413 | Xpressnet | xpressnet | __**[[:xpressnet-en|Li-USB]]**__ |  57600 | +
-| COM5 | /dev/ttyACM2 | /dev/tty.usbmodem1415 | Dr.Command (Setup) |  -  |  -  |  -  | +
- +
-**After successful configuration, several other commonly used protocol types can be used with Rocrail.** +
- \\ +
-====Setup USB LocoNet Rocrail==== +
-{{:dr5000:rocrail_controller_dr5000-en.png|}} \\ +
-{{:dr5000:dr5000_loconet_interface-en.png?281|}} {{:dr5000:dr5000_loconet_options-en.png?281|}} {{:dr5000:dr5000_loconet_details-en.png?281|}} \\ +
-More details are described below. \\ +
- +
- +
-====Setup LAN====+
 LocoNet, LNTCP, is recommended for the DR5000 communication. (Xpressnet seems to be too slow and is missing some events.)\\ LocoNet, LNTCP, is recommended for the DR5000 communication. (Xpressnet seems to be too slow and is missing some events.)\\
 ====LocoNet LAN==== ====LocoNet LAN====
Line 50: Line 30:
 (Error message: Trace timer timed out for OPCODE 0xB0, to fix: increase timer)\\ (Error message: Trace timer timed out for OPCODE 0xB0, to fix: increase timer)\\
 - the time between switching on the system and starting Rocrail is too short, the DR 5000 should be left for a few moments until everything is ready for operation. \\ - the time between switching on the system and starting Rocrail is too short, the DR 5000 should be left for a few moments until everything is ready for operation. \\
-===Options=== 
-Some LocoNet Throttles do not set an ID and therefore the Speed will not be updated in the Rocrail clients. (Rocview, andRoc, Rocweb...)\\ 
-See: __**[[:rocrailini-automode-en#allow_zero_throttle_id|Zero Throttle ID]]**__ for more information about this issue.\\ 
  
  \\  \\
  
 +====Loconet Options====
 +{{:dr5000:dr5000-loconet-options.png?500}}\\
 +\\
 +
 +Select "ibcom" Command Station to support functions 9...28.
 +
 +Some LocoNet Throttles do not set an ID and therefore the Speed will not be updated in the Rocrail clients. (Rocview, andRoc, Rocweb…)
 +See: Zero Throttle ID for more information about this issue __**[[:rocrailini-automode-en#Allow zero Throttle ID |Zero Throttle ID]]**__
 +
 + \\
 ====LocoNet Details==== ====LocoNet Details====
-{{:loconet:loconet-details-en.png}}\\+{{:dr5000:dr5000-loconet-details-en.png?500}}\\
 ===Wait for slot data=== ===Wait for slot data===
 This number should be increased, max. 128, if the following error occurs: This number should be increased, max. 128, if the following error occurs:
Line 65: Line 52:
 Default Rocrail will read up to 16 packets until it give up waiting for a free slot.\\ Default Rocrail will read up to 16 packets until it give up waiting for a free slot.\\
 This figure, the default of 16, seems to be too low for the DR5000.\\ This figure, the default of 16, seems to be too low for the DR5000.\\
 +
 +===Other Options===
 +|< >|
 +^ Option ^ Recommended Value ^
 +| Switch time | 50ms |
 +| Slot ping | Off |
 +| Fast clock | Off |
  
  
  \\  \\
 ====Z21==== ====Z21====
 +See for Z21 library settings __**[[:roco:roco-z21-en|Roco Z21]]**__.\\
 +
 +**Note:** //Power, voltage and temp. are not reported; No measurement hardware available.//\\
 ===DR5088RC=== ===DR5088RC===
 If using the Z21 protocol in combination with DR5088RC there is a shift in reported feedback and block(RailCom) addressing.\\ If using the Z21 protocol in combination with DR5088RC there is a shift in reported feedback and block(RailCom) addressing.\\
Line 75: Line 72:
  
  
 + \\
  
 +=====Setup USB=====
 +{{:dr5000:dr5000-usb.png}}
  \\  \\
 +====Devices=====
 +Following serial devices are added for the DR5000:
 +^ Windows ^ Linux & RaspBerry Pi ^ Mac OS X ^ Protocol ^ Library ^ Sub-Library / Type ^ Baudrate ^
 +| COM4 | /dev/ttyACM0 | /dev/tty.usbmodem1411 | LocoNet | loconet | __**[[:loconet-cs-en|LocoBuffer]]**__ |  57600 |
 +| COM6 | /dev/ttyACM1 | /dev/tty.usbmodem1413 | Xpressnet | xpressnet | __**[[:xpressnet-en|Li-USB]]**__ |  57600 |
 +Users who want to use the interface must be added to the ''dialout'' group. See **[[:faq-en#serial_device_user_access_linux|Serial device user access (Linux)]]**.
 +\\
 +**After successful configuration, several other commonly used protocol types can be used with Rocrail.**
 + \\
 +====Setup USB LocoNet Rocrail====
 +{{:dr5000:dr5000-controller-en.png|}} \\
 +{{:dr5000:dr5000-loconet-interface-en.png?281|}} {{:dr5000:dr5000-loconet-options.png?263|}} {{:dr5000:dr5000-loconet-details-en.png?263|}} \\
 +More details are described below. \\
  
-====DrCmd==== 
-{{ :dr5000:drcmd-log-en.png?300}} 
-12.740+\\ 
-The **drcmd** library has only limited support because the protocol is not documented.\\ 
-===Supported commands:=== 
-  * Power ON/OFF 
-  * Switch (FADA only) 
-  * Loco speed, direction and F0-F28 
-  * Programming Track 
-  * POM 
-===Supported events:=== 
-  * S88 reporting 
-  * Switch reporting 
-  * Power events 
-  * Current and temperature 
-  * Loco speed, direction and F0 reporting 
  
- \\ 
- 
-====Xpressnet LAN==== 
-  * __**[[:xpressnet-en|Li-ETH]]**__ 
  \\  \\
  
 =====Addressing===== =====Addressing=====
 +====Sensors====
 +**Tip:** Use the [[:sensormon-en|Sensor Monitor]] to find the right address.\\
 +
 ====Accessory==== ====Accessory====
 //Switches, Outputs and Signals.//\\ //Switches, Outputs and Signals.//\\
dr5000-en.1585683948.txt.gz · Last modified: 2020/03/31 21:45 by smitt48