gca102-en [2018/12/09 16:21] – [Firmware] phg | gca102-en [2019/03/27 10:15] – [Remarks on GCA102v3 used with hall sensors] peter_basti | ||
---|---|---|---|
Line 116: | Line 116: | ||
| {{: | | {{: | ||
^^ | ^^ | ||
- | + | ^GCA102V3 (green pcb) files ^ | |
+ | | {{ : | ||
+ | | {{ : | ||
+ | | {{: | ||
+ | | {{: | ||
+ | \\ | ||
\\ | \\ | ||
Line 135: | Line 140: | ||
Control it from GCA50 or other I/O units with puls control like switches with coil control.\\ | Control it from GCA50 or other I/O units with puls control like switches with coil control.\\ | ||
Board needs 5Volt supply to pin1&2 of J2, and pin3 and 4 are control inputs.\\ | Board needs 5Volt supply to pin1&2 of J2, and pin3 and 4 are control inputs.\\ | ||
- | Only J1(partly), J2, K1, U2, JP1, and the two diodes | + | See partslist for GCA102V3\\ |
- | \\ | + | 1 hall sensor should be positioned on both sides of both rail separation cuts., with a distance so,\\ |
+ | that a hall sensor is activated BEFORE first wheels | ||
+ | {{: | ||
+ | \\{{ : | ||
===== Cable to GCA50 / CAN-GC2 / GCA_PI02===== | ===== Cable to GCA50 / CAN-GC2 / GCA_PI02===== | ||
Line 188: | Line 196: | ||
===== Firmware ===== | ===== Firmware ===== | ||
| {{: | | {{: | ||
- | | {{ :: | + | | {{:gca: |