gca:wioprog2-en
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
gca:wioprog2-en [2020/11/25 14:16] – [Description] phg | gca:wioprog2-en [2023/09/25 11:03] (current) – [Jumper settings] phg | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== WIO_Prog2 DCC central station with 2 x 3,5 amp output and programming track option. ====== | ====== WIO_Prog2 DCC central station with 2 x 3,5 amp output and programming track option. ====== | ||
+ | [[english|{{ : | ||
+ | * [[: | ||
+ | * [[: | ||
+ | * [[: | ||
{{ : | {{ : | ||
- | [[english|{{ : | ||
\\ | \\ | ||
Line 11: | Line 14: | ||
* Programming track 1 Amp maximum current | * Programming track 1 Amp maximum current | ||
* Fastled control | * Fastled control | ||
- | * CAN bus | + | * Isolated |
- | * RocNet | + | * WIO |
- | * Standard | + | * I2C bus (standard and RocNet) |
* Rocrail control via WIFI, CAN or USB | * Rocrail control via WIFI, CAN or USB | ||
- | * Standard I2C bus | ||
* Railcom capable with GCA214 detector | * Railcom capable with GCA214 detector | ||
* two rail outputs each 3,5 Amp (1 Amp in programming mode) | * two rail outputs each 3,5 Amp (1 Amp in programming mode) | ||
Line 30: | Line 32: | ||
WIO_prog2 can be controlled from Rocrail via WIFI, USB and CAN. \\ | WIO_prog2 can be controlled from Rocrail via WIFI, USB and CAN. \\ | ||
The used firmware is the same firmware as for all WIO units, using Lolin D1 or D32 (Arduino related) modules.\\ | The used firmware is the same firmware as for all WIO units, using Lolin D1 or D32 (Arduino related) modules.\\ | ||
- | \\ | + | \\ |
+ | ===== Loco Node-ID==== | ||
+ | DCC Locomotives must be set IID to WIO and Node-ID to the ID of the WIO-Prog2.\\ | ||
+ | |||
+ | |||
+ | |||
+ | \\ | ||
===== further info ===== | ===== further info ===== | ||
Since this board is using same firmware as other WIO related units, the complete concept\\ | Since this board is using same firmware as other WIO related units, the complete concept\\ | ||
Line 36: | Line 44: | ||
[[ https:// | [[ https:// | ||
===== Hardware ===== | ===== Hardware ===== | ||
- | | {{ :gca:wio_prog2_sch.pdf |The schematics }} | | + | | {{ :gca:wio_prog2_V3_sch.pdf |The schematics }} | |
| {{ : | | {{ : | ||
| {{: | | {{: | ||
+ | | {{ : | ||
+ | \\ | ||
+ | ===== Jumper settings ===== | ||
+ | ^ JP1 ^ Maximum current selector | ||
+ | | 1-2 connected | ||
+ | | 2-3 connected | ||
+ | \\ | ||
+ | ^ JP2 + JP3 ^ IIC pull up for bus driver | ||
+ | | 1-2 connected | ||
+ | | 2+3 connected | ||
+ | \\ | ||
+ | ^ JP4 CAN bus terminator | ||
+ | | set this jumper when CAN bus is used, and this unit is on one end of the CAN line | | ||
+ | \\ | ||
+ | |||
+ | |||
+ |
gca/wioprog2-en.1606310162.txt.gz · Last modified: 2020/11/25 14:16 by phg