known_switch_coils_and_their_technical_details [2018/11/12 08:56] – external edit 127.0.0.1
Line 1: Line 1:
 +===== Electrical details about turnout coils =====
 +[[english|{{  rocrail-logo-35.png}}]]
  
 +[[english|Content]] -> [[hardware-en|Hardware]] -> [[hardware-en#interfaces|GCA]]
 +  *  [[mgv-overview-en|The GCA modules]] 
 +
 + \\
 +
 +^^^^By Peter Giling ^^^^
 +
 +
 +The list below is just an indication to help you choosing the right Interface for your turnouts.\\
 +This list is composed by surfing the internet.\\
 +No responsibility can be taken for the accuracy of this list.\\
 +Most of these turnout coils are made to be used with ac transformer.\\
 +Using them in Digital systeem means that they will be powered by DC, causing a slightly higher current through the coil.\\
 +In case of any doubts, always refer to the original manual of your turnouts.\\
 +To be more accurate the voltage is indicated which is used for measuring the current.\\
 +
 +^  Mark  ^  type #  ^  Testvoltage  ^  current  \\  ( in amps)  ^  Ohms  ^  remarks  ^  Useable with  ^
 +|  Märklin  |  C-rails all types |  18V  |  >1, |  11 Ohm  |  the best idea here is to remove switches inside  \\  solonoid drive. The installed switch can handle only 0.5 Amp \\  see specs : [[http://www.produktinfo.conrad.com/datenblaetter/700000-724999/705622-da-01-de-ULTRAMINIATUR_DH2C_B1PA_0_5A_30V.pdf|microswitch]]  |  GCA76  |
 +|  Märklin  |  K-rails 7549 |  18V  |  1,2  |  15 Ohm  |  |  GCA76  |
 +|  Märklin  |  M-rails  |  18V  |  0,5  |  32 Ohm  |  |  GCA77/GCA76  |
 +|  Roco  |  61195  |  18V  |  1  |  17 Ohm  |  |   GCA76  |  
 +|  Fleischmann  |  6421  |  18V  |  0,9  |  17 Ohm |  |  GCA76  |
 +|  Fleischmann Piccolo  |  9182  |  16V  |  0,9  |  14 Ohm  |  |  GCA76  |
 +|  Trix  |  Minitrix 14971  |  16V  |  1,2  |  7 Ohm  |  When sufficient 12V supply is used   \\  possible with GCA77  |  GCA77/GCA76  |
 +|  Tillig  |  HO scale  |  18V  |  0,6  |  23 Ohm  |  |  GCA76  | 
known_switch_coils_and_their_technical_details.txt · Last modified: 2020/04/15 14:00 by phg