loc-int-en [2019/09/13 16:14] – [Placing] rjversluisloc-int-en [2019/12/10 16:18] rainerk
Line 28: Line 28:
   *Marklin mfx-Decoders may need special settings depending on the command station. See the wiki page of the relevant command station, if applicable.   *Marklin mfx-Decoders may need special settings depending on the command station. See the wiki page of the relevant command station, if applicable.
   *Locos with address 0 (zero) are considered to be analog locos without decoders which are only supported by TrackDriver systems. "Stretched 0 Bit" according to NEM 670 is not supported.   *Locos with address 0 (zero) are considered to be analog locos without decoders which are only supported by TrackDriver systems. "Stretched 0 Bit" according to NEM 670 is not supported.
-The optional second address can be used for T4T (TrainCoupling&CommunicationSystem).\\+====Secondary Address==== 
 +The optional secondary address can be used for **[[:arduino:wio-en#mobile|WIO]]** or T4T (TrainCoupling&CommunicationSystem).\\
 ====OID==== ====OID====
 Some Command Station, like the ESU Ecos, are using an Object ID instead of an address for referring to a specific loco.\\ Some Command Station, like the ESU Ecos, are using an Object ID instead of an address for referring to a specific loco.\\
Line 38: Line 39:
 Some command stations do support multiple protocols; Check the user manual for details.\\ Some command stations do support multiple protocols; Check the user manual for details.\\
 If the __address is set to zero__ the protocol should be set to **Analog** for __**[[:block-int-en|Track Driver]]**__ support.\\  If the __address is set to zero__ the protocol should be set to **Analog** for __**[[:block-int-en|Track Driver]]**__ support.\\ 
- \\+ 
 +**Note:** //Serverdefined, is the default mobile digital protocol used by the Command Station (CS). 
 +This setting is only of interest in case of multi protocol CS like Ecos/CSx(dcc/mfx). 
 +For a "DCC only" CS this option has no effect at all. 
 +Or for the Märklin 6051 its always Motorola. // 
 + 
  
 =====Protocol version===== =====Protocol version=====
Line 73: Line 79:
 This can be done with the [[https://www.z21.eu/de/downloads/software-tools|Roco Videolok utility]].\\ This can be done with the [[https://www.z21.eu/de/downloads/software-tools|Roco Videolok utility]].\\
 The port must be set to 5152.\\ The port must be set to 5152.\\
 +**Note:** //It can take up to 30 seconds before the first frames are coming in after starting the camera.//\\
 {{:roco:roco-videolok-utility-clientmode.png?240}}\\ {{:roco:roco-videolok-utility-clientmode.png?240}}\\
 +
 ====Demo & Links==== ====Demo & Links====
   * Demo: https://youtu.be/6A57b-VoOSw   * Demo: https://youtu.be/6A57b-VoOSw
Line 84: Line 92:
 =====Options===== =====Options=====
 ====Mass==== ====Mass====
-Only to be used when this is an analog loco in combination of the Dinamo CS. (Check the documentation.) \\+Can be used
 +  * When this is an analog loco in combination of the Dinamo CS. (Check the documentation.) 
 +  * A WIO with the mobile option activated. 
 +  * A RocNetNode mobile decoder
 A value of 5 is a good start to experiment with. A value of 5 is a good start to experiment with.
  \\  \\
Line 95: Line 106:
 :!: Use with care. This option is __not recommended__ and __not supported in the Forum__, and uses unnecessary CPU resources. :!: :!: Use with care. This option is __not recommended__ and __not supported in the Forum__, and uses unnecessary CPU resources. :!:
  \\  \\
 +====Invert====
 +Inverts the hardware running direction.\\
 +This is an alternative to program the direction in the decoder by CV29.\\
 +<html><!--
 ====Placing==== ====Placing====
 //Placing is the __logical__ forward direction.// \\ //Placing is the __logical__ forward direction.// \\
-When the loco runs the wrong direction this flag can be swapped.\\+When the loco runs the wrong direction this flag can be swapped. This flag is not fixed and can change during automatic runs.\\
 For commuters this flag is automatically swapped in __**[[:block-gen-en#terminal_station|terminal station block types]]**__ and for routes in the opposite direction.\\  For commuters this flag is automatically swapped in __**[[:block-gen-en#terminal_station|terminal station block types]]**__ and for routes in the opposite direction.\\ 
 This flag is default set and means a Loco run direction like coming out of the box; some older decoders do only remember the direction for a short period after shut-down the power.\\ This flag is default set and means a Loco run direction like coming out of the box; some older decoders do only remember the direction for a short period after shut-down the power.\\
Line 104: Line 119:
  
 Read also: **[[:direction-en|Direction in Rocrail]]** Read also: **[[:direction-en|Direction in Rocrail]]**
 +--></html>
 ====Polarisation==== ====Polarisation====
 A flag for correcting the BiDi, RailCom, direction in case the decoders is not correctly polarised. \\ A flag for correcting the BiDi, RailCom, direction in case the decoders is not correctly polarised. \\
 See also: __**[[:rocrailini-automode-en#use_bidi_direction|BiDi Direction]]**__ \\ See also: __**[[:rocrailini-automode-en#use_bidi_direction|BiDi Direction]]**__ \\
  
- +====Step range==== 
- +If __**[[arduino:wio-en#mobile|WIO as Mobile decoder]]**__ be used, this can simulate Vstart and Vhigh, CV2/CV5.\\
- \\+
 =====Acceleration===== =====Acceleration=====
 ====Adjust acceleration==== ====Adjust acceleration====
loc-int-en.txt · Last modified: 2024/04/18 02:15 by rainerk