ContentCommand StationsCAN


State channels, A/V/C, will be polled every 5 seconds, and in case of a change reported to the Rocrail Server.
The TrackBox/CS3/Booster can be added to the Power Manger with the UID.


TrackBox

Channel Usage Resolution Range
1 Current 1mA 0…2.5A
3 Voltage 100mV 0…27V
4 Temperature 1C° 0…80°C


CS3

Channel Usage Resolution Range
1 Current main 8mA 0…5.5A
2 Current programming track 3mA 0…2.3A
3 Voltage 40mV 0…27V
4 Temperature 0.414C° 0…80°C
7 S88-Bus connected modules 1 0…31


Booster 6017x

Channel Usage Resolution Range
1 Current main 8.475mA 0…5.5A
2 Voltage 41mV 0…27V
3 Temperature 0.414C° 0…80°C


LinkS88

Channel Usage Resolution Range
2 RJ45 Bus-1 connected modules 1 0…31
3 RJ45 Bus-2 connected modules 1 0…31
4 S88 Bus-3 connected modules (6-pin connector) 1 0…31