User Tools

Site Tools


mbus:cs3-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
mbus:cs3-en [2019/03/16 10:38] – [Switch/Output] rjversluismbus:cs3-en [2022/05/01 10:40] (current) – [Switch/Output] rjversluis
Line 1: Line 1:
-======MBUS CS3======+======MBUS CS2/CS3======
 [[:english#command_stations|{{  :interface.png}}]][[:english|{{  :rocrail-logo-35.png}}]] [[:english#command_stations|{{  :interface.png}}]][[:english|{{  :rocrail-logo-35.png}}]]
-[[:english|Content]] -> [[:english#command_stations|Command Stations]] -> **[[:english#can|CAN]]** +[[:english|Content]] -> **[[:english#command_stations|Command Stations]]** -> Märklin 
-  * **[[:mbus:mbus-en|MBUS]]** +  * **[[:mbus:mbus2-en|MBUS]]** 
-    * [[:mbus:functions-en|Function Codes]] | **[[:mbus:cs3-en|CS3]]** | [[:mbus:channels-en|Channels]]+    * [[:mbus:functions-en|Function Codes]] | **[[:mbus:cs3-en|CS2/CS3]]** |  [[:mbus:mbus-en|TrackBox(GleisBox)]] | [[:mbus:channels-en|Channels]]
 {{:mbus:cs3plus.png?200}}\\ {{:mbus:cs3plus.png?200}}\\
 +
 +^  The MCS2 library is replaced by the MBus library. 
  
 =====TCP Communication===== =====TCP Communication=====
Line 14: Line 16:
 ====Communication Type==== ====Communication Type====
 The preferred way to communicate with the CS3 is by using the TCP type.\\ The preferred way to communicate with the CS3 is by using the TCP type.\\
 +The CS3 TCP port is factory set to 15731, the second port is not utilized.\\
 +Classic CS2 UDP communication uses two port numbers, sending (Tx) and receiving (Rx). \\
 +If the port entry is set to zero, it is automatically replaced with the default values, 15731 and 15730. \\
 {{:mbus:mbus-interface-en.png}}\\ {{:mbus:mbus-interface-en.png}}\\
-The CS3 TCP port is factory set to 15731.\\+
 ====Overview==== ====Overview====
 If all went well, the CS3 is listed in the CBUS/MBUS dialog:\\ If all went well, the CS3 is listed in the CBUS/MBUS dialog:\\
Line 23: Line 28:
  \\  \\
 =====Sensors===== =====Sensors=====
 +====Poll at SoD====
 +Use only in case of Gleisreporter de Luxe.\\
 +
 ====S88 CS2/CS3plus==== ====S88 CS2/CS3plus====
 This setup is needed to be able to detect the sensor state at start up.\\ This setup is needed to be able to detect the sensor state at start up.\\
Line 37: Line 45:
  \\  \\
 ====LinkS88==== ====LinkS88====
-|  //Starting with revision 15.073, this setup is no longer needed; Its detected automatically.//  |\\ +|  //This setup is no longer needed; Its detected automatically.//  |\\ 
-This setup is needed to be able to detect the sensor state at start up.\\+<del>This setup is needed to be able to detect the sensor state at start up.</del>
 |{{:mbus:links88-setup-de.png?0x240}}|{{:mbus:mbus-sensors-en.png?0x240}}|\\ |{{:mbus:links88-setup-de.png?0x240}}|{{:mbus:mbus-sensors-en.png?0x240}}|\\
 An entry in the list is needed for each connected LinkS88 device.\\ An entry in the list is needed for each connected LinkS88 device.\\
Line 52: Line 60:
 Turn this option off in all other cases.\\ Turn this option off in all other cases.\\
    
 +
 +====Auto switch delay====
 +A switch delay time is always send in case this option is active. (Default active)\\
 +This is independent of the individual [[:switch-int-en#switch_time|Switch Time]]. The global switch delay is used if the individual switch time is set to zero.\\
 + \\
 +=====Switch time=====
 +__**[[:switch-int-en#switch_time|Activate this timer in case the motor does not switch itself off!]]**__ \\
 +:!: Disabled end contacts will burn the coils of the motor if the switch time is not activated.\\
 +
  
  \\  \\
 =====Addressing===== =====Addressing=====
 ====Switch/Output==== ====Switch/Output====
-An example for CS2/3 switch address **11**:+An example for the real switch address **12**:
 |< >| |< >|
-^ Type ^ Address ^ Port ^ Calculation +^ Type ^ Address ^ Port ^ Remark 
-^ MADA |   3 |   4 |  (3-1)*4+(4-1)=11 +^ MADA |   3 |   4 | Not supported! 
-^ PADA |   |  12((Same as the display address in the CS2/GUI.))  12-1=11 |+^ PADA |   |  12 Same scheme as the display address in the CS2/CS3 GUI. | 
 +^ FADA |   |   - | Not supported! |
  
  \\  \\
Line 85: Line 103:
  
  \\  \\
-=====ToDo===== 
-  * [✔] Read A/V/T channels 
-  * Read out the Loco database 
-  * [✔] LinkS88 SoD 
-  * [✔] CS3plus S88 SoD 
-  * [✔] Power on at startup 
-  * [✔] Auto detect devices and there properties, linke LinkS88: Device ID and number of modules. 
-  * [✔] Multi booster support (Reporting A/V/C) 
  
mbus/cs3-en.1552729115.txt.gz · Last modified: 2019/03/16 10:38 by rjversluis