mbus:cs3-en
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
mbus:cs3-en [2020/10/09 16:16] – rjversluis | mbus:cs3-en [2022/05/01 10:40] (current) – [Switch/Output] rjversluis | ||
---|---|---|---|
Line 2: | Line 2: | ||
[[: | [[: | ||
[[: | [[: | ||
- | * **[[:mbus:mbus-en|MBUS]]** | + | * **[[:mbus:mbus2-en|MBUS]]** |
* [[: | * [[: | ||
{{: | {{: | ||
+ | |||
+ | ^ The MCS2 library is replaced by the MBus library. | ||
=====TCP Communication===== | =====TCP Communication===== | ||
Line 14: | Line 16: | ||
====Communication Type==== | ====Communication Type==== | ||
The preferred way to communicate with the CS3 is by using the TCP type.\\ | The preferred way to communicate with the CS3 is by using the TCP type.\\ | ||
+ | The CS3 TCP port is factory set to 15731, the second port is not utilized.\\ | ||
+ | Classic CS2 UDP communication uses two port numbers, sending (Tx) and receiving (Rx). \\ | ||
+ | If the port entry is set to zero, it is automatically replaced with the default values, 15731 and 15730. \\ | ||
{{: | {{: | ||
- | The CS3 TCP port is factory set to 15731.\\ | + | |
====Overview==== | ====Overview==== | ||
If all went well, the CS3 is listed in the CBUS/MBUS dialog:\\ | If all went well, the CS3 is listed in the CBUS/MBUS dialog:\\ | ||
Line 40: | Line 45: | ||
\\ | \\ | ||
====LinkS88==== | ====LinkS88==== | ||
- | | //Starting with revision 15.073, this setup is no longer needed; Its detected automatically.// | + | | //This setup is no longer needed; Its detected automatically.// |
- | This setup is needed to be able to detect the sensor state at start up.\\ | + | <del>This setup is needed to be able to detect the sensor state at start up.</ |
|{{: | |{{: | ||
An entry in the list is needed for each connected LinkS88 device.\\ | An entry in the list is needed for each connected LinkS88 device.\\ | ||
Line 55: | Line 60: | ||
Turn this option off in all other cases.\\ | Turn this option off in all other cases.\\ | ||
+ | |||
+ | ====Auto switch delay==== | ||
+ | A switch delay time is always send in case this option is active. (Default active)\\ | ||
+ | This is independent of the individual [[: | ||
\\ | \\ | ||
=====Switch time===== | =====Switch time===== | ||
- | __**[[: | + | __**[[: |
:!: Disabled end contacts will burn the coils of the motor if the switch time is not activated.\\ | :!: Disabled end contacts will burn the coils of the motor if the switch time is not activated.\\ | ||
Line 64: | Line 73: | ||
=====Addressing===== | =====Addressing===== | ||
====Switch/ | ====Switch/ | ||
- | An example for the real switch address **11**: | + | An example for the real switch address **12**: |
|< >| | |< >| | ||
- | ^ Type ^ Address ^ Port ^ Calculation | + | ^ Type ^ Address ^ Port ^ Remark ^ |
- | ^ MADA | 3 | 4 | | + | ^ MADA | 3 | 4 | Not supported! |
- | ^ PADA | 0 | 12 | | + | ^ PADA | 0 | 12 | Same scheme as the display address in the CS2/CS3 GUI. | |
- | ^ FADA | - | - | Not supported! | + | ^ FADA | - | |
\\ | \\ | ||
Line 94: | Line 103: | ||
\\ | \\ | ||
+ |
mbus/cs3-en.1602252983.txt.gz · Last modified: 2020/10/09 16:16 by rjversluis