User Tools

Site Tools


mbus:mbus-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
mbus:mbus-en [2019/07/29 20:24] – [Type] phgmbus:mbus-en [2020/04/18 16:21] – [Tips] phg
Line 10: Line 10:
 The Command Station, Märklin TrackBox(GleisBox), is economically priced and supports the digital **DCC/MfX/MM2** protocols. A Mobile Station can be used as throttle and programmer.\\ The Command Station, Märklin TrackBox(GleisBox), is economically priced and supports the digital **DCC/MfX/MM2** protocols. A Mobile Station can be used as throttle and programmer.\\
  
-====Overview==== 
-{{mbus:mbus-socketcan.jpeg?400}}\\ 
 ====Devices==== ====Devices====
-{{ :arduino:gc2a-module.jpg?200}}{{ :mbus:ms2.png}}+{{ :mbus:ms2.png}}
   * Raspberry Pi + Rocrail Server + __**[[:rocnet:pi01can-en|Pi01CAN]]**__ or __**[[:cbus:socketcan-en|RPI-CAN]]**__   * Raspberry Pi + Rocrail Server + __**[[:rocnet:pi01can-en|Pi01CAN]]**__ or __**[[:cbus:socketcan-en|RPI-CAN]]**__
   * or Banana Pi M1 + Rocrail Server + [[http://lnxpps.de/bpi/|BPi CAN]]    * or Banana Pi M1 + Rocrail Server + [[http://lnxpps.de/bpi/|BPi CAN]] 
-  * __**[[:arduino:rcan-en|CANGC2a]]**__ 16 I/O 
   * Märklin TrackBox(GleisBox) [[https://www.maerklin.de/de/produkte/details/article/60116|60116]] [[https://www.maerklin.de/de/produkte/details/article/60113|60113]]   * Märklin TrackBox(GleisBox) [[https://www.maerklin.de/de/produkte/details/article/60116|60116]] [[https://www.maerklin.de/de/produkte/details/article/60113|60113]]
   * Märklin Mobile Station [[https://www.maerklin.de/de/produkte/details/article/60657|60657]] (Optional)   * Märklin Mobile Station [[https://www.maerklin.de/de/produkte/details/article/60657|60657]] (Optional)
Line 30: Line 27:
 //"For small systems."//\\ //"For small systems."//\\
 The company [[https://www.gridconnect.com|Grid Connect]] defined an ASCII framing protocol designed for using frames over serial connections.\\ The company [[https://www.gridconnect.com|Grid Connect]] defined an ASCII framing protocol designed for using frames over serial connections.\\
-The USB connection of the __**[[:arduino:rcan-en|CANGC2a]]**__ can be used for this type.\\ 
 Fixed baud rate of 500000.\\ Fixed baud rate of 500000.\\
 ===SocketCAN=== ===SocketCAN===
Line 99: Line 95:
  
 ===Master=== ===Master===
-**Note:** MS2 Firmware 3.55 does negotiate different compared with previous versions. (Not supported yet.)\\+**Note:** MS2 Firmware 3.55 and higher does negotiate differentcompared with previous versions. This none conform update will be not supported.\\
 **Note:** //Master mode will be disabled in case a CS2/CS3 is detected.//\\  **Note:** //Master mode will be disabled in case a CS2/CS3 is detected.//\\ 
 Puts the connected MS2 in slave mode and provide loco information.\\ Puts the connected MS2 in slave mode and provide loco information.\\
Line 128: Line 124:
 All addressing schemes are supported. (FADA/PADA/MADA)\\ All addressing schemes are supported. (FADA/PADA/MADA)\\
 The bus value **must** be set to zero.\\ The bus value **must** be set to zero.\\
-====GC2a==== 
-  * Bus = CAN-ID 
-  * Address = GC2a port number, 1...16 
- 
- \\ 
- 
-=====GC2a Signal support===== 
-This is for simple signals up to 4 LED and max. 5 aspects.\\ 
-Only the RED address will be used as offset for all LEDs.\\ 
-|< >| 
-^ Parameter ^ Description ^ 
-| Control | Aspect numbers | 
-| Port type | LED | 
-| Bus | CAN-ID of the GC2a | 
-| Addressing | FLAT from 1 to 16 - number of aspects | 
- 
-====Aspect Values==== 
-See: __**[[:signal-props-en#value|Aspect Values]]**__ \\ 
-The number of controlled LEDs will be calculated from the aspect values.\\ 
- 
-===Example=== 
-===Aspect value examples=== 
-|< >| 
-^ Value (dec) ^ LEDs ^ 
-| 0x01 (1) | LED 1 on | 
-| 0x02 (2) | LED 2 on | 
-| 0x04 (4) | LED 3 on | 
-| 0x08 (8) | LED 4 on | 
-| 0x11 (17) | LED 1 blinking | 
-| 0x55 (85) | LED 1 and 3 blinking | 
-| 0x03 (3) | LED 2 and LED 1 on | 
-| 0x13 (19) | LED 2 on and LED 1 blinking | 
- 
  
  \\  \\
  
 =====Tips===== =====Tips=====
-  * Note: In order to show changes of loco functions in Rocview option **[[:rocrailini-automode-en#allow_zero_throttle_id|Allow Zero Throttle ID]]** has to be activated.+  * Note: In order to show changes of loco functions in Rocviewoption **[[:rocrailini-automode-en#allow_zero_throttle_id|Allow Zero Throttle ID]]** has to be activated.
mbus/mbus-en.txt · Last modified: 2022/02/10 22:05 by rjversluis