User Tools

Site Tools


mgv:lm-draaischijf

MGV LM "De Draaischijf"

User pagesModelspoorGroep Venlo



module 21 module 22

File naam: draaischijf.*
Moduul code: m7


Rocrail

Connections

Function Code Adress MGV50 adr. Terminal #
Turnout 7t1 15 7-1 1
Feedback 7f1 69 7-1 9
Feedback 7f2 70 7-1 10
Sign red 7s1 215 7-1 7
Sign gr/ye 7s1 216 7-1 8
Turnout 7t2 16 7-2 1
Feedback 7f3 71 7-2 9
Feedback 7f4 72 7-2 10
Sign red 7s2 213 7-2 7
Sign gr/ye 7s2 214 7-2 8


Feedbacks

7f 1 2 3 4
Adress 69 70 71 72
MGV50 adr. 7-1 7-1 7-2 7-2
Terminal # 9 10 9 10


Blocks & Feedbacks

Blok Nr enter pre-in in Occupied
7b1 69 0 72 0
7b2 71 0 70 0
7b3 0 0 0 0


Turnouts

Code Adress MGV50 adr. Terminal #
7t1 15 21-1 1
7t2 16 22-1 1


Signs

Function Code Adress MGV50 adr. Terminal
red sign 7s1 215 7-1 7
gr/ye sign 7s1 216 7-1 8
red sign 7s2 213 7-2 7
gr/ye sign 7s2 214 7-2 8


Truth table sign 7s1

Function Address 215 Address 216
red 0 1
green 1 1
yellow 1 0


Truth table sign 7s2

Function Address 213 Address 214
red 0 1
green 1 1
yellow 1 0


Turntable

Adress Function
224 pos bit 0
225 pos bit 1
226 pos bit 2
227 pos bit 3
228 pos bit 4
229 adress enable
230 turntable in position
231 ??

Since we are going to realise our own system here, I like to make control equal to fiddle yard. This means 1 byte total for control. If we take 32 possible positions, we need 5 bits for position, plus 1 for enable is 6 bits.

2 bits left for handshaking.

Do we need a name for that byte?

Connections display

Display M7

Address MGV50 Function Control Address Indication Terminal # Programming
7/101 block detection 69 7f3 1 block occupancy
7/101 block detection 69 7f3 2 block occupancy
7/101 block detection 70 7f2 3 block occupancy
7/101 block detection 70 7f2 4 block occupancy
7/101 block detection 71 7f1 5 block occupancy
7/101 block detection 71 7f1 6 block occupancy
7/101 block detection 72 7f4 7 block occupancy
7/101 block detection 72 7f4 8 block occupancy
7/101 turnout 15 7t2 9 2 Off
7/101 turnout 16 7t1 10 2 Off
7/101 turnout 17 7t3 11 2 Off
7/101 sign red 213 7s2 12 1 On
7/101 sign gr/yel 214 7s2 13 1 On
7/101 sign red 215 7s1 14 1 On
7/101 sign gr/yel 216 7s1 15 1 On
7/101 2048 16 block occupancy
mgv/lm-draaischijf.txt · Last modified: 2018/11/12 08:56 by 127.0.0.1