User Tools

Site Tools


roco:roco-z21-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
roco:roco-z21-en [2018/12/08 07:53] – [Accessories] rjversluisroco:roco-z21-en [2019/01/07 12:18] – [Power Manager] rjversluis
Line 78: Line 78:
 ^ Bus ^ Network ^ Z21 Firmware ^ Remark ^ ^ Bus ^ Network ^ Z21 Firmware ^ Remark ^
 |  0 | R-Bus |  1.0  | | |  0 | R-Bus |  1.0  | |
-|  1 | LocoNet Input |  1.2  | LocoIO, DR5088RC(Feedback) +|  1 | LocoNet |  1.2  | LocoIO, DR5088RC(Feedback)GBM16XN, DR5088RC(Block) |
-|  1 | LocoNet Multi Sense |  1.2  | GBM16XN, DR5088RC(Block) |+
 |  3 | CAN |  1.29  | Roco Z21 CAN Detector | |  3 | CAN |  1.29  | Roco Z21 CAN Detector |
 ===Flat addressing=== ===Flat addressing===
Line 86: Line 85:
 ...\\ ...\\
  \\  \\
- 
 ====Special Feature ==== ====Special Feature ====
 In the default setting of the z21 / Z21 there is an address offset of +4 between Multimaus and Rocrail. This means that in Rocrail the addresses 1-4 can not be used. If e.g. address 1 of the multimouse is to be used in Rocrail address 5. But there is an elegant way to eliminate this shift. To do this, connect the z21 to the computer via the z21-maintenance-tool, activate the option "DCC-switch address shift +4" resp. "DCC tournout-addressing according to RCN-213" on the "Settings" tab and then confirm with "Write". Then the addresses from 1 can also be used in Rocrail. Addressing is done exclusively according to FADA (flat addressing). \\ In the default setting of the z21 / Z21 there is an address offset of +4 between Multimaus and Rocrail. This means that in Rocrail the addresses 1-4 can not be used. If e.g. address 1 of the multimouse is to be used in Rocrail address 5. But there is an elegant way to eliminate this shift. To do this, connect the z21 to the computer via the z21-maintenance-tool, activate the option "DCC-switch address shift +4" resp. "DCC tournout-addressing according to RCN-213" on the "Settings" tab and then confirm with "Write". Then the addresses from 1 can also be used in Rocrail. Addressing is done exclusively according to FADA (flat addressing). \\
  \\  \\
  
-=====Rocrail & GBM16XN=====+=====GBM16XN===== 
 +| :!: **Activate only in case of GBM16XN detectors!** | 
 +This option will activate evaluating LAN_LOCONET_DETECTOR messages to support the GBM16XN detectors.\\ 
 +The reported input address is increased with one to meet the GBM16XN settings. This conflicts with normal LocoNet!\\
 Z21 firmware: 1.24+\\ Z21 firmware: 1.24+\\
-See for setup: http://www.z21.eu/content/download/1134/12993/file/Z21_GBM16XN.pdf \\ 
  
  
  \\  \\
 +===== Power Manager=====
 +To add the Z21 to the __**[[:powerman-en|Power Manger]]**__:\\
 +{{roco:z21-booster-en.png}}\\
 +The address is fixed to 21.\\
 +{{roco:z21-powerman-en.png}}\\
  
 +
 +
 + \\
 ===== Trouble Shooting ===== ===== Trouble Shooting =====
 ==== LAN ==== ==== LAN ====
roco/roco-z21-en.txt · Last modified: 2023/05/15 09:33 by cds