User Tools

Site Tools


roco:roco-z21-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
roco:roco-z21-en [2020/11/29 18:01] – [Hostname] rjversluisroco:roco-z21-en [2023/05/15 09:33] (current) – [LocoNet detectors] cds
Line 10: Line 10:
 =====Z21/z21 Firmware===== =====Z21/z21 Firmware=====
 [[http://www.z21.eu/News/Aktuelle-News/Aktualisieren-Sie-Ihr-Maintenance-Tool|Update the Z21/z21 firmware.]]\\ [[http://www.z21.eu/News/Aktuelle-News/Aktualisieren-Sie-Ihr-Maintenance-Tool|Update the Z21/z21 firmware.]]\\
 +
 +
 + \\
 +===== Notes =====
 +  * LocoNet sensor modules from Digikeijs seems not compatible with the Z21.
  
  \\  \\
Line 23: Line 28:
   * 28 Loco functions   * 28 Loco functions
   * Switch/Output commands   * Switch/Output commands
-  * Timed switch commands for coils¹+  * Timed switch commands for coils ((Commands for the same address are rejected in case the timer did not yet elapsed.))
   * Sensor report evaluation   * Sensor report evaluation
   * Switch report evaluation   * Switch report evaluation
Line 30: Line 35:
   * Programming RMBus   * Programming RMBus
   * CAN Z21 10808 detector support   * CAN Z21 10808 detector support
- \\ 
-¹) //Commands for the same address are rejected in case the timer did not yet elapsed.//\\ 
  \\  \\
 +
  
 ===== Setup ===== ===== Setup =====
Line 39: Line 43:
 ====Hostname/IP-Adresse==== ====Hostname/IP-Adresse====
 Factory default is 192.168.0.111 which is also used if left empty.\\ Factory default is 192.168.0.111 which is also used if left empty.\\
-| //The Z21 does not support DHCP, so in this field the IP Address of the Z21 must be set.// | 
  
 ====Port==== ====Port====
Line 47: Line 50:
  
 ====Locomotives==== ====Locomotives====
 +:!: //Only use this option in case locomotives are controlled by an external throttle which connects directly to the Z21/z21.//\\
 This option is needed for getting (speed, direction and function) info events from the Command Station of manually((External throttle)) controlled locos to synchronize Rocrail clients.\\ This option is needed for getting (speed, direction and function) info events from the Command Station of manually((External throttle)) controlled locos to synchronize Rocrail clients.\\
 Without this option the subscription on loco info is done individually for each loco after a speed or function command is send from Rocrail.\\  Without this option the subscription on loco info is done individually for each loco after a speed or function command is send from Rocrail.\\ 
  
  
-====Xpressnet GBM==== +
-This option must be set if RailCom detectors are connected to the Xpressnet bus of the z21.\\ +
-(Blücher GBM16XN) +
- \\+
 ==== Report absent ==== ==== Report absent ====
 If this option is activated, it will be reported if a loco ID is no longer recognized by a RailCom detector. If this option is activated, it will be reported if a loco ID is no longer recognized by a RailCom detector.
   \\   \\
 +
 +==== Check Hostname ====
 +| :!: Disable this option, and use the static Z21 IP address, if no sensor events are coming in. :!: |
 +Use this option only if the Z21 the static IP address has been assigned a hostname.\\
 +In all other cases this option should be deactivated.\\
 +**Note:** //For Network experts only!// 
 + \\
 +====Booster events====
 +This option must be activated, if Booster events should be received from the the z21 controller. 
 + \\
 +====LocoNet detectors====
 +This option should only be activated if RailCom detectors are connected to the LocoNet bus of the z21 controller.\\
 +It activates OPC_MULTI_SENSE events. For more information see capital **9.5** //LAN_LOCONET_DETECTOR// in the Z21 Protocol Specs.\\
 +**Note:** //Leave this option disabled in case no RailCom detectors are connected.//\\
 + \\
 +====multiMAUS====
 +Check if the event is originated by the multiMAUS to signal Rocrail that it is a field event.\\
 +
 ====Program FB==== ====Program FB====
 {{ :roco:z21-10787.jpg?400}} {{ :roco:z21-10787.jpg?400}}
Line 66: Line 85:
   - :!: Program address zero after the sensor module has acknowledged.   - :!: Program address zero after the sensor module has acknowledged.
  
 +==== Switch time ==== 
 +Default output activation time for switches.\\ 
 +This value is only used in case the __**[[:switch-int-en#switch_time|Switch time]]**__ for a individual turnout is zero.\\ 
 +**Note:** //The output of the switch will only be reset after this time in case its activated.//\\
  
  \\  \\
Line 78: Line 100:
 |  1 | Loconet |  1.2  | |  1 | Loconet |  1.2  |
 Switches, outputs and signals do only use the address field.\\ Switches, outputs and signals do only use the address field.\\
 +:!: If both address and port are set > 0 the addressing will be recalculated back to FADA. This is not recommended. (2.1.1577+)\\
  
 ====Sensors==== ====Sensors====
 +**Tip:** Use the [[:sensormon-en|Sensor Monitor]] to find the right address.\\
 +
 ^ Bus ^ Network ^ Z21 Firmware ^ Remark ^ ^ Bus ^ Network ^ Z21 Firmware ^ Remark ^
 |  0 | R-Bus |  1.0  | | |  0 | R-Bus |  1.0  | |
-|  1 | LocoNet |  1.2  | LocoIO, DR5088RC(Feedback), GBM16XN, DR5088RC(Block) |+|  1 | LocoNet |  1.2  | LocoIO, DR5088RC(Feedback), DR5088RC(Block) |
 |  3 | CAN |  1.29  | Roco Z21 CAN Detector | |  3 | CAN |  1.29  | Roco Z21 CAN Detector |
 ===Flat addressing=== ===Flat addressing===
Line 90: Line 115:
  \\  \\
 ====Special Feature ==== ====Special Feature ====
-In the default setting of the z21 / Z21 there is an address offset of +4 between Multimaus and Rocrail. This means that in Rocrail the addresses 1-4 can not be used. If e.g. address 1 of the multimouse is to be used in Rocrail address 5. But there is an elegant way to eliminate this shift. To do this, connect the z21 to the computer via the z21-maintenance-tool, activate the option "DCC-switch address shift +4" resp. "DCC tournout-addressing according to RCN-213" on the "Settings" tab and then confirm with "Write". Then the addresses from 1 can also be used in Rocrail. Addressing is done exclusively according to FADA (flat addressing). \\+In the default setting of the z21 / Z21 there is an address offset of +4 between Multimaus and Rocrail. This means that in Rocrail the addresses 1-4 can not be used. If e.g. address 1 of the multimouse is to be used in Rocrail address 5. But there is an elegant way to eliminate this shift. To do this, connect the z21 to the computer via the z21-maintenance-tool, activate the option "DCC-switch address shift +4" resp. "DCC tournout-addressing according to RCN-213" on the "Settings" tab and then confirm with "Write". Then the addresses from 1 can also be used in Rocrail. Addressing is done exclusively according to __**[[:addressing-en#flat_accessory_decoder_address_fada|FADA (Flat addressing)]]**__.
  \\  \\
  
-=====GBM16XN===== 
-| :!: **Activate only in case of GBM16XN detectors!** | 
-This option will activate evaluating LAN_LOCONET_DETECTOR messages to support the GBM16XN detectors.\\ 
-The reported input address is increased with one to meet the GBM16XN settings. This conflicts with normal LocoNet!\\ 
-Z21 firmware: 1.24+\\ 
  
- 
- \\ 
 ===== Power Manager===== ===== Power Manager=====
 To add the Z21 to the __**[[:powerman-en|Power Manger]]**__:\\ To add the Z21 to the __**[[:powerman-en|Power Manger]]**__:\\
roco/roco-z21-en.1606669265.txt.gz · Last modified: 2020/11/29 18:01 by rjversluis