rocrailini-automode-en
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
rocrailini-automode-en [2020/05/02 16:09] – [Automode] smitt48 | rocrailini-automode-en [2024/02/27 07:41] (current) – [Check electrification] rjversluis | ||
---|---|---|---|
Line 2: | Line 2: | ||
[[: | [[: | ||
[[:english | Content ]] -> [[: | [[:english | Content ]] -> [[: | ||
- | * [[: | + | * [[: |
Line 8: | Line 8: | ||
| A restart of the server is required in order for changes to take effect! | | | A restart of the server is required in order for changes to take effect! | | ||
\\ | \\ | ||
- | {{: | + | {{: |
Line 39: | Line 39: | ||
====Stop none commuter in terminal==== | ====Stop none commuter in terminal==== | ||
Stop the auto mode of none commuter trains after the **IN** event in a terminal station to be able to manually run around the locomotive to the other side of the consist.\\ | Stop the auto mode of none commuter trains after the **IN** event in a terminal station to be able to manually run around the locomotive to the other side of the consist.\\ | ||
- | |||
- | ====Force unlock at EBreak==== | ||
- | All routes and switches will be forced unlocked after an Emergency Break.\\ | ||
====Close block on ghost==== | ====Close block on ghost==== | ||
Line 76: | Line 73: | ||
====Enable block power check==== | ====Enable block power check==== | ||
At locking a block it will be checked if it has power If the block is part of a __**[[: | At locking a block it will be checked if it has power If the block is part of a __**[[: | ||
+ | |||
+ | |||
+ | ====Check electrification==== | ||
+ | Check if the block is **[[: | ||
==== Min Block - Train length ==== | ==== Min Block - Train length ==== | ||
Line 104: | Line 105: | ||
==== Ignore events within... ==== | ==== Ignore events within... ==== | ||
- | **Enter**-events are filtered out if they are in the same time frame as specified in the field. (field value x 10ms)\\ | + | Sensor |
==== Use Bi-Directional Communication ==== | ==== Use Bi-Directional Communication ==== | ||
Line 115: | Line 116: | ||
Enables the option for delayed off sensor event.\\ | Enables the option for delayed off sensor event.\\ | ||
{{: | {{: | ||
+ | |||
+ | ==== Generate unregistered sensors ==== | ||
+ | Activate this option if BiDiB hardware systems expect acknowledge of feedback from addresses that are not defined in Rocrail. So that the acknowledgement is possible, temporary sensor objects are created for the undefined address data. | ||
+ | |< >| | ||
+ | | :!: **Attention: | ||
+ | |||
+ | ==== Ignore events within ==== | ||
+ | **Enter**-Events will be filtered out, if they occure in the defined Time range (Value in ticks of 10ms). \\ | ||
+ | \\ | ||
====Event timeout==== | ====Event timeout==== | ||
Line 129: | Line 139: | ||
\\ | \\ | ||
- | =====Routing===== | + | =====Locality===== |
+ | ====Exclude==== | ||
+ | A CSV list of automatic excluded locations.\\ | ||
+ | This can be useful if a locomotive is in an offstage location to prevent commands.\\ | ||
+ | |||
+ | \\ | ||
+ | =====Route===== | ||
====No speed change for switches==== | ====No speed change for switches==== | ||
If the route contains thrown switches the signal will be set to white (yellow with three aspects signals) and the loco velocity will set to **V_mid**.\\ | If the route contains thrown switches the signal will be set to white (yellow with three aspects signals) and the loco velocity will set to **V_mid**.\\ | ||
Line 144: | Line 160: | ||
====Synchronize routes==== | ====Synchronize routes==== | ||
Force setting one route at a time, regarding the [[# | Force setting one route at a time, regarding the [[# | ||
+ | **Note:** //This option is __NOT__ compatible with **[[: | ||
====Use Finder for destination path==== | ====Use Finder for destination path==== | ||
Line 157: | Line 174: | ||
Schedules not re-started after the auto mode is stopped.\\ | Schedules not re-started after the auto mode is stopped.\\ | ||
+ | ==== Location Prioritization==== | ||
+ | If activated (default) the Location __**[[locations-details-en# | ||
====Select shortest block==== | ====Select shortest block==== | ||
If train and block length are set this option will choose the shortest block available for that train.\\ | If train and block length are set this option will choose the shortest block available for that train.\\ | ||
Line 171: | Line 190: | ||
====Enable Router==== | ====Enable Router==== | ||
Special option to disable the Router for a demo server.\\ | Special option to disable the Router for a demo server.\\ | ||
+ | |||
+ | ====Force unlock at EBreak==== | ||
+ | All routes and switches will be forced unlocked after an Emergency Break.\\ | ||
====Route switch time==== | ====Route switch time==== | ||
Line 184: | Line 206: | ||
==== Route synchronizer timeout ==== | ==== Route synchronizer timeout ==== | ||
When the option [[# | When the option [[# | ||
+ | |||
+ | ==== (Set) timeout ==== | ||
+ | The global timeout (in seconds) to wait for setting all commands in a route.\\ | ||
+ | An exception message " | ||
+ | Default set to zero: Not used.\\ | ||
+ | This value can be overwritten by the **[[: | ||
+ | |||
==== Virtual timer ==== | ==== Virtual timer ==== | ||
Time in seconds between the **enter2in** events for the __**[[: | Time in seconds between the **enter2in** events for the __**[[: | ||
Range: 2-60 seconds.\\ | Range: 2-60 seconds.\\ | ||
+ | |||
==== Calculate ==== | ==== Calculate ==== | ||
Line 229: | Line 259: | ||
* ZimoBIN | * ZimoBIN | ||
====Send zero speed command at power on==== | ====Send zero speed command at power on==== | ||
- | To trigger Railcom decoders to use channel 2 which is needed when two or more are in the same detection section.\\ | + | The V0 command is only send if the loco speed is already zero and the first power on in this session.\\ |
- | This command is only send if the loco speed is already zero.\\ | + | **Note**: //This could be helpful to trigger Railcom decoders to use channel 2 which is needed when two or more are in the same detection section.//\\ |
==== Reset speed and functions ==== | ==== Reset speed and functions ==== | ||
Line 259: | Line 289: | ||
====Restore schedule==== | ====Restore schedule==== | ||
Restore the last used schedule at startup.\\ | Restore the last used schedule at startup.\\ | ||
+ | |||
+ | |||
+ | ====Restore reservation==== | ||
+ | Restore and reserve the saved goto block at startup.\\ | ||
==== Loco start gap ==== | ==== Loco start gap ==== | ||
Line 276: | Line 310: | ||
Supported Systems: | Supported Systems: | ||
* __**[[: | * __**[[: | ||
+ | * WIO | ||
* __**[[: | * __**[[: | ||
+ | |||
+ | ====Check if restore is ready==== | ||
+ | This will prevent switching on the automatic mode before all locos did restore functions and speed.\\ | ||
====Action timer 60 sec.==== | ====Action timer 60 sec.==== | ||
Use a 60 second interval for evaluating action timers.\\ | Use a 60 second interval for evaluating action timers.\\ | ||
Line 349: | Line 387: | ||
====Switch safe position timer==== | ====Switch safe position timer==== | ||
- | Timer (in seconds) to reset the switches to their __**[[: | + | Timer (in seconds) to reset the switches to their __**[[: |
+ | A value of zero will disable this option in automatic mode.\\ | ||
+ | \\ | ||
+ | =====CTC===== | ||
+ | ====CTC Events==== | ||
+ | Enable CTC events. Disable this option incase it uses too much processing power.\\ | ||
+ | ====CTC Occupancy priority==== | ||
+ | Default the route color will beset also in case the block has been occupied.\\ |