rocrailini-automode-en [2020/05/27 01:35] – Missing option added rainerkrocrailini-automode-en [2024/02/27 07:41] (current) – [Check electrification] rjversluis
Line 2: Line 2:
 [[:english#rocrail|{{  :server.png}}]][[:english|{{  :rocrail-logo-35.png}}]] [[:english#rocrail|{{  :server.png}}]][[:english|{{  :rocrail-logo-35.png}}]]
 [[:english | Content ]] -> [[:english#rocrail|Rocrail Server]] -> [[:rocrailini-en | Configuration]]  [[:english | Content ]] -> [[:english#rocrail|Rocrail Server]] -> [[:rocrailini-en | Configuration]] 
-  * [[:rocrailini-gen-en|General]] | [[:rocrailini-trace-en|Trace]] | [[:rocrailini-service-en|Service]] |  **Automatic** | [[:rocrailini-controller-en|Controller]] | [[:networking-en|R2Rnet]] | [[:rocrailini-router-en|Router]] | [[:rocrailini-rocweb-en|RocWeb]] | [[:finder:finder-en|Finder]] | [[:rocrailini-cmdmapping-en|Command Mapping]]+  * [[:rocrailini-gen-en|General]] | [[:rocrailini-trace-en|Trace]] | [[:rocrailini-service-en|Service]] |  **Automatic** | [[:rocrailini-controller-en|Controller]] | [[:networking-en|R2Rnet]] | [[:rocrailini-rocweb-en|RocWeb]] | [[:finder:finder-en|Finder]] | [[:rocrailini-cmdmapping-en|Command Mapping]]
  
  
Line 39: Line 39:
 ====Stop none commuter in terminal==== ====Stop none commuter in terminal====
 Stop the auto mode of none commuter trains after the **IN** event in a terminal station to be able to manually run around the locomotive to the other side of the consist.\\ Stop the auto mode of none commuter trains after the **IN** event in a terminal station to be able to manually run around the locomotive to the other side of the consist.\\
- 
-====Force unlock at EBreak==== 
-All routes and switches will be forced unlocked after an Emergency Break.\\ 
  
 ====Close block on ghost==== ====Close block on ghost====
Line 76: Line 73:
 ====Enable block power check==== ====Enable block power check====
 At locking a block it will be checked if it has power If the block is part of a __**[[:powerman-en|Booster District]]**__.\\ At locking a block it will be checked if it has power If the block is part of a __**[[:powerman-en|Booster District]]**__.\\
 +
 +
 +====Check electrification====
 +Check if the block is **[[:block-gen-en#electrified_catenary|Electrified]]** in case an electric driven locomotive wants to reserve the block.\\
  
 ==== Min Block - Train length ==== ==== Min Block - Train length ====
Line 116: Line 117:
 {{:eventtimeout.png?100}}\\ {{:eventtimeout.png?100}}\\
  
-=== Generate unregistered sensors ====+==== Generate unregistered sensors ====
 Activate this option if BiDiB hardware systems expect acknowledge of feedback from addresses that are not defined in Rocrail. So that the acknowledgement is possible, temporary sensor objects are created for the undefined address data. Activate this option if BiDiB hardware systems expect acknowledge of feedback from addresses that are not defined in Rocrail. So that the acknowledgement is possible, temporary sensor objects are created for the undefined address data.
 |< >| |< >|
-| :!: **Attention:** //__The option must only be activated if it is required.__ In other cases, malfunctions are possible, e.g. RocNetNode.// | \\+| :!: **Attention:** //__The option should only be activated if it is necessary.__ In other cases, malfunctions are possible, e.g. RocNetNode.// | \\
  
 ==== Ignore events within ==== ==== Ignore events within ====
Line 138: Line 139:
  
  \\  \\
-=====Routing=====+=====Locality===== 
 +====Exclude==== 
 +A CSV list of automatic excluded locations.\\ 
 +This can be useful if a locomotive is in an offstage location to prevent commands.\\  
 + 
 + \\ 
 +=====Route=====
 ====No speed change for switches==== ====No speed change for switches====
 If the route contains thrown switches the signal will be set to white (yellow with three aspects signals) and the loco velocity will set to **V_mid**.\\ If the route contains thrown switches the signal will be set to white (yellow with three aspects signals) and the loco velocity will set to **V_mid**.\\
Line 153: Line 160:
 ====Synchronize routes==== ====Synchronize routes====
 Force setting one route at a time, regarding the [[#route_synchronizer_timeout|Route synchronizer timeout]], to reduce power consumption and switch decoder overload with multiple outputs.\\ Force setting one route at a time, regarding the [[#route_synchronizer_timeout|Route synchronizer timeout]], to reduce power consumption and switch decoder overload with multiple outputs.\\
 +**Note:** //This option is __NOT__ compatible with **[[:block-gen-en#fifo|FiFo blocks]]**.//\\
  
 ====Use Finder for destination path==== ====Use Finder for destination path====
Line 166: Line 174:
 Schedules not re-started after the auto mode is stopped.\\ Schedules not re-started after the auto mode is stopped.\\
  
 +==== Location Prioritization====
 +If activated (default) the Location __**[[locations-details-en#flow_management|flow management]]**__ has preference, if not set the routes priorities take precedence.\\
 ====Select shortest block==== ====Select shortest block====
 If train and block length are set this option will choose the shortest block available for that train.\\ If train and block length are set this option will choose the shortest block available for that train.\\
Line 180: Line 190:
 ====Enable Router==== ====Enable Router====
 Special option to disable the Router for a demo server.\\ Special option to disable the Router for a demo server.\\
 +
 +====Force unlock at EBreak====
 +All routes and switches will be forced unlocked after an Emergency Break.\\
  
 ====Route switch time==== ====Route switch time====
Line 193: Line 206:
 ==== Route synchronizer timeout ==== ==== Route synchronizer timeout ====
 When the option [[#synchronize_routes|Synchronize routes]] is active, Rocrail will wait with setting a second route, but only for the timeout time specified. When the timeout time has expired the route will be set, regardless whether or not the setting of the first route has finished.\\ When the option [[#synchronize_routes|Synchronize routes]] is active, Rocrail will wait with setting a second route, but only for the timeout time specified. When the timeout time has expired the route will be set, regardless whether or not the setting of the first route has finished.\\
 +
 +==== (Set) timeout ====
 +The global timeout (in seconds) to wait for setting all commands in a route.\\
 +An exception message "2060" will appear in the Rocview server panel if the timeout is exceeded. The exception can be processed by a **[[:actionctrl-en#state|system action]]**.\\
 +Default set to zero: Not used.\\
 +This value can be overwritten by the **[[:route-gen-en#set_timeout|Set Timeout]]** value in the route properties.\\
 +
  
 ==== Virtual timer ==== ==== Virtual timer ====
 Time in seconds between the **enter2in** events for the __**[[:virtual-automatic-en|Virtual Automatic]]**__.\\ Time in seconds between the **enter2in** events for the __**[[:virtual-automatic-en|Virtual Automatic]]**__.\\
 Range: 2-60 seconds.\\ Range: 2-60 seconds.\\
 +
  
 ==== Calculate ==== ==== Calculate ====
Line 238: Line 259:
   * ZimoBIN   * ZimoBIN
 ====Send zero speed command at power on==== ====Send zero speed command at power on====
-To trigger Railcom decoders to use channel 2 which is needed when two or more are in the same detection section.\\ +The V0 command is only send if the loco speed is already zero and the first power on in this session.\\ 
-This command is only send if the loco speed is already zero.\\+**Note**: //This could be helpful to trigger Railcom decoders to use channel 2 which is needed when two or more are in the same detection section.//\\
  
 ==== Reset speed and functions ==== ==== Reset speed and functions ====
Line 268: Line 289:
 ====Restore schedule==== ====Restore schedule====
 Restore the last used schedule at startup.\\ Restore the last used schedule at startup.\\
 +
 +
 +====Restore reservation====
 +Restore and reserve the saved goto block at startup.\\
  
 ==== Loco start gap ==== ==== Loco start gap ====
Line 285: Line 310:
 Supported Systems: Supported Systems:
   * __**[[:rocnet:rocnetnode-en|RocNetNode]]**__   * __**[[:rocnet:rocnetnode-en|RocNetNode]]**__
 +  * WIO
   * __**[[:zimocan-en|Zimo MX10]]**__ (WIP)   * __**[[:zimocan-en|Zimo MX10]]**__ (WIP)
  
 +
 +====Check if restore is ready====
 +This will prevent switching on the automatic mode before all locos did restore functions and speed.\\
 ====Action timer 60 sec.==== ====Action timer 60 sec.====
 Use a 60 second interval for evaluating action timers.\\ Use a 60 second interval for evaluating action timers.\\
Line 358: Line 387:
  
 ====Switch safe position timer==== ====Switch safe position timer====
-Timer (in seconds) to reset the switches to their __**[[:switch-gen-en#safe_switch_position|Safe Switch Position]]**__. +Timer (in seconds) to reset the switches to their __**[[:switch-gen-en#safe_switch_position|Safe Switch Position]]**__.\\ 
 +A value of zero will disable this option in automatic mode.\\
  
  
 + \\
 +=====CTC=====
 +====CTC Events====
 +Enable CTC events. Disable this option incase it uses too much processing power.\\
 +====CTC Occupancy priority====
 +Default the route color will beset also in case the block has been occupied.\\
rocrailini-automode-en.1590536123.txt.gz · Last modified: 2020/05/27 01:35 by rainerk