rascii-en
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
rascii-en [2019/08/13 08:31] – [Arduino] rjversluis | rascii-en [2022/12/11 00:48] (current) – obsolete trouble shooting section removed rainerk | ||
---|---|---|---|
Line 3: | Line 3: | ||
[[: | [[: | ||
\\ | \\ | ||
- | {{: | + | {{: |
+ | |||
+ | \\ | ||
+ | =====Setup===== | ||
+ | {{: | ||
+ | ====Options==== | ||
+ | ===Ping=== | ||
+ | A Ping command will be sent with this interval in ms.\\ | ||
+ | Disabled in case of zero.\\ | ||
+ | The Ping can be used as "Dead man's switch" | ||
\\ | \\ | ||
Line 23: | Line 32: | ||
The info text may not contain any of the prefixes. This will make the message invalid and will be rejected.\\ | The info text may not contain any of the prefixes. This will make the message invalid and will be rejected.\\ | ||
- | \\ | + | ====Serial Monitor==== |
+ | Serial monitor input is a way to provide easy setting up a unit, for example the WiFi settings.\\ | ||
+ | The input should be read until a linefeed has been detected, and do not have a length field. | ||
+ | === Help=== | ||
+ | |< >| | ||
+ | ^ Prefix ^ Remark ^ | ||
+ | | ? | Should show help regarding monitor commands. | | ||
+ | ===CV=== | ||
+ | |< >| | ||
+ | ^ Prefix ^ Example ^ Remark ^ | ||
+ | | * | '' | ||
+ | |||
+ | |||
+ | \\ | ||
=====HEXA===== | =====HEXA===== | ||
HEXA is the Hexadecimal-ASCII representation of a binary number.\\ | HEXA is the Hexadecimal-ASCII representation of a binary number.\\ | ||
Line 89: | Line 111: | ||
| 12 | # | Accessory | Address, Port, aspect((0=straight, | | 12 | # | Accessory | Address, Port, aspect((0=straight, | ||
| 13 | # | Mobile speed | Address-High, | | 13 | # | Mobile speed | Address-High, | ||
- | | 14 | # | Mobile function | Address-High, | + | | 14 | # | Mobile function | Address-High, |
- | | | + | | 37 | # | PT ON | none | A remark. | |
- | | | + | | 38 | # | PT OFF | none | A remark. |
- | | 126 | # | Poll RS485 | none | Queued event, reply or an ACK if the queue is empty. | | + | | |
- | | 127 | # | Acknowledge | Code | none | | + | | |
\\ | \\ | ||
Line 116: | Line 138: | ||
\\ | \\ | ||
- | =====Trouble shooting===== | ||
- | ====Windows crash nach Rocrail start==== | ||
- | Some Windows configurations will crash at Rocrail server startup if the Arduino is connected by USB and the following option is not set:\\ | ||
- | * __**[[: | ||
- | |||
- | |||
- | |||
- |
rascii-en.1565677917.txt.gz · Last modified: 2019/08/13 08:31 by rjversluis