stageblock:stage-details-en
Differences
This shows you the differences between two versions of the page.
— | stageblock:stage-details-en [2025/03/09 09:35] (current) – created - external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ======Staging Block Details ====== | ||
+ | [[: | ||
+ | [[: | ||
+ | * [[: | ||
+ | \\ | ||
+ | |||
+ | \\ | ||
+ | ===== Details ===== | ||
+ | These settings are except for the Arrive speed only for the last section where the train starts running in auto mode again.\\ | ||
+ | {{: | ||
+ | See **[[: | ||
+ | ====Minimal occupied==== | ||
+ | ===Trains=== | ||
+ | The train in the last section may only depart if the number of trains in this staging block is more or equal to this number.\\ | ||
+ | ===Sections=== | ||
+ | The second field is the number of sections which must be __electrically occupied__ before the first train is allowed to leave.\\ | ||
+ | |||
+ | \\ | ||
+ | ====Best choice==== | ||
+ | This option will help to get trains choosing this staging block instead of other blocks.\\ | ||
+ | A random choice will happen if more than one available block to choose from has this option.\\ | ||
+ | |||
+ | ====In event at train length==== | ||
+ | Generate the **in** event if the train completely fits in the staging block instead of reaching the destination section to free up the previous block.\\ | ||
+ | **Note:** //With this option active the wait time will be ignored if no other locomotives are in the stage block.//\\ | ||
+ | |||
+ | |||
+ | ====Electrified==== | ||
+ | This option can be activated for staging blocks equipped with a catenary. \\ | ||
+ | If NOT set this prevents locos with **engine type electric** (see **[[: | ||
+ | |||
+ | ====Watchdog==== | ||
+ | Checks every x seconds if auto mode is enabled and if the head section is free and one or more trains are in the staging block to trigger compression.\\ | ||
+ | Compression is normally triggered by sensor events and lock/unlock commands, but under certain conditions this is not possible and in this case the watchdog will trigger it.\\ | ||
+ | The check interval in seconds can be set in the field at the right side of this option.\\ | ||
+ | ===Timeout=== | ||
+ | Pending compression timeout in seconds if set greater then zero.\\ | ||
+ | |||
+ | \\ | ||
+ | =====Wait===== | ||
+ | ====Type==== | ||
+ | The wait type for the locomotive in the last section.\\ | ||
+ | Avoid using **None** or a very short wait time, in combination with a manual operated exit signal to prevent unnecessary data traffic.\\ | ||
+ | \\ | ||
+ | |||
+ | =====Speed===== | ||
+ | ====Arrive==== | ||
+ | The minimal speed is default and should be used if the sections are relative short.\\ | ||
+ | Both other speed options can be used, as the initial arriving speed, if there is enough room behind the section sensor to decelerate from Vmid to V0; Use with care.\\ | ||
+ | :!: **Please note:** Between the sections, the train always advances with the Arrive speed (Vmin, Vmid or %). \\ | ||
+ | Into the last section of an Compress action and into the last section of the Staging block, a train always drives with Vmin.\\ | ||
+ | |||
+ | Numerical selection is used by speed selection of %. \\ | ||
+ | |||
+ | ===Use arrive speed to target section=== | ||
+ | This option __overrules__ the Vmin to the last section of an Compress action and into the last section of the Staging block, and uses the arrive speed.\\ | ||
+ | ===Vmin to first section=== | ||
+ | Lok advances with Vmin to the end of the first section, if the subsequent sections are occupied. | ||
+ | \\ | ||
+ | ====Depart==== | ||
+ | The depart speed of the locomotive in the last section. | ||
+ | |||
+ | \\ | ||
+ | |||
+ | ===== Commands (Right mouse click)===== | ||
+ | |||
+ | ==== Compress (move up)==== | ||
+ | * Advance the occupying trains with the selected Arrive speed (Vmin, Vmid or %) towards the end section, to fill up gaps and make room at the start. | ||
+ | * Turn on the auto mode of the train waiting in the end section if the exit state is open. | ||
+ | |||
+ | ==== Close/Open exit ==== | ||
+ | Controls the output flow, exit, of the staging block.\\ | ||
+ | |||
+ | ==== In/Out of Operation ==== | ||
+ | Controls the input flow, enter, of the staging block.\\ | ||