 +====== LocoNet Parameter Summary ======
 +[[:​english#​command_stations|{{ ​ :​interface.png}}]][[:​english|{{ ​ :​rocrail-logo-35.png}}]]
 + 
 +[[:​english|Content]] -> [[:​english#​command_stations|Command Stations]] -> [[:​loconet-en| Digitrax LocoNet]]  ​
 +  * **[[:​loconet:​ln-pe-en|Protocol]]** | [[:​loconet-cs-en|Command Stations]] | [[:​loconet-interfaces-en|Interfaces]] | [[:​loconet-dev-en|Devices]] | [[:​locont-wi-en|Wiring]]
 +    * **Parameters**
 +// \\ // \\ 
 + \\
  
 +===== Copyright =====
 +LocoNet® Personal Use version definitions 1.0\\
 +All Copyrights and rights reserved, Digitrax 1997\\
 +
 + \\
 +
 +===== Parameters =====
 +^  Name  ^  Description ​ ^  Bits/​Range ​ ^
 +| **ADR** ​ | 7 bit loco address | short address, CV18 if ADR2 > 0|
 +| **ADR2** ​ | 7 bit high loco address | 0=short address, CV17 |
 +| **SW1** ​ | 7 ls switch address bits | 0,​A6,​A5,​A4,​A3,​A2,​A1,​A0 |
 +| **SW2** ​ | 4 ms switch address and control bits | 0,​0,​DIR,​ON,​A10,​A9,​A8,​A7 |
 +|          | DIR, switch direction | 1=closed(green),​ 0=thrown(red) | 
 +|          | ON, switch activation | output 1=ON, 0=OFF | 
 +| **SLOT** | 7 bit slot number | 0..127 |
 +| **SRC** ​ | 7 bit source slot number | 0..127 |
 +| **DEST** | 7 bit destination slot number | 0..127 |
 +| **SL1** ​ | 7 bit slave slot number | 0..127 |
 +| **SL2** ​ | 7 bit master slot number | 0..127 |
 +| **SPD** |  speed | 0x00=SPEED 0 ,STOP\\ 0x01=SPEED 0 EMERGENCY stop\\ 0x02-0x7F increasing SPEED,​0x7F=MAX speed |
 +| **DIRF** | loco direction and functions(4) | 0,​0,​DIR,​F0,​F4,​F3,​F2,​F1 |
 +| **SND** | slot sound | 0,​0,​0,​0,​F8,​F7,​F6,​F5 |
 +| **STAT1** | slot status containing speed steps | See below |
 +| **SS2** ​ | slot status 2 | 0,​0,​0,​0,​D3,​D2,​0,​D0 |
 +|          | D0 | 1=this slot has suppressed ADV consist |
 +|          | D2 | 1=expansion ID1/2 is not ID usage |
 +|          | D3 | 1=expansion IN ID1/2, 0=encoded alias |
 +| **LOPC** | copy of opcode | bit 7 is set to zero |
 +| **ACK1** | response code | 0=failed |
 +| **IN1** | sensor address | 0,​A6,​A5,​A4,​A3,​A2,​A1,​A0 |
 +| **IN2** | sensor address and status | 0,​X,​I,​L,​A10,​A9,​A8,​A7 |
 +|         | X, control bit | 0=reserved for future |
 +|         | I, input source | 0=DS54, 1=switch |
 +|         | L, sensor level | 0=low, 1=high |
 +| **SN1** | turnout sensor address | 0,​A6,​A5,​A4,​A3,​A2,​A1,​A0 |
 +| **SN2** | turnout sensor address and status | 0,​1,​I,​L,​A10,​A9,​A8,​A7 |
 +|         | I, input source | 0=aux, 1=switch |
 +|         | L, sensor level | 0=low, 1=high |
 +| **SN2** | alternately turnout sensor address and status | 0,​0,​C,​T,​A10,​A9,​A8,​A7 |
 +|         | C, closed output | 0=OFF, 1=ON |
 +|         | T, thrown output | 0=OFF, 1=ON |
 +| **ID1** | throttle/PC ID if SS2.4=1 | 7 bit ls |
 +| **ID2** | throttle/PC ID if SS2.4=1 | 7 bit ms |
 +
 +
 + \\
 +====Slot Status 1====
 +  * **D7-SL_SPURGE**
 +    * 1=SLOT purge en,ALSO adrSEL (INTERNAL use only, not seen on NET!)\\ CONDN/​CONUP:​ bit encoding-Control double linked Consist List
 +
 + \\
 +===2 BITS for Consist===
 +  * **D6-SL_CONUP**
 +  * **D3-SL_CONDN**
 +    * 11=LOGICAL MID CONSIST , Linked up AND down
 +    * 10=LOGICAL CONSIST TOP, Only linked downwards
 +    * 01=LOGICAL CONSIST SUB-MEMBER, Only linked upwards
 +    * 00=FREE locomotive, no CONSIST indirection/​linking\\ ALLOWS "​CONSISTS of CONSISTS"​. Uplinked means that Slot SPD number is now SLOT adr of SPD/DIR and STATUS of consist. i.e. is an Indirect pointer. This Slot has same BUSY/ACTIVE bits as TOP of Consist. TOP is loco with SPD/DIR for whole consist. (top of list). BUSY/​ACTIVE:​ bit encoding for SLOT activity
 +
 + \\
 +===2 BITS for BUSY/​ACTIVE===
 +  * **D5-SL_BUSY**
 +  * **D4-SL_ACTIVE**
 +    * 11=IN_USE loco adr in SLOT -REFRESHED
 +    * 10=IDLE loco adr in SLOT, not refreshed
 +    * 01=COMMON loco adr IN SLOT, refreshed
 +    * 00=FREE SLOT, no valid DATA, not refreshed
 +
 + \\
 +===3 BITS for Decoder TYPE encoding for this SLOT===
 +  * **D2-SL_SPDEX**
 +  * **D1-SL_SPD14**
 +  * **D0-SL_SPD28**
 +    * 010=14 step MODE
 +    * 001=28 step. Generate Trinary packets for this Mobile ADR
 +    * 000=28 step/ 3 BYTE PKT regular mode
 +    * 011=128 speed mode packets
 +    * 111=128 Step decoder, Allow Advanced DCC consisting
 +    * 100=28 Step decoder ,Allow Advanced DCC consisting
 +
 +
 +
 + \\
 +
 +===== Slots =====
 +^ Nr.  ^ Description ​ ^
 +|          0 | dispatch |
 +|    1 - 119 | active locos |  ​
 +|  120 - 127 | reserved for System and Master control |
 +|        123 | Fast Clock |
 +|        124 | Programming Track |
 +|        127 | Command Station Options |
 +
 +
 + \\
 +===== Programmer track =====
 +The programmer track is accessed as Special slot #124 ( $7C, 0x7C). It is a full asynchronous shared
 +system resource.\\
 +To start Programmer task, write to slot 124. There will be an immediate LACK acknowledge that
 +indicates what programming will be allowed. If a valid programming task is started, then at the final
 +(asynchronous) programming completion, a Slot read <E7> from slot 124 will be sent. This is the final
 +task status reply.
 + \\
 +
 +==== Parameters ====
 +^  Name  ^  Description ​ ^  Bits/​Range ​ ^
 +| **ACK1¹** | response code | 0=busy/​aborted,​ 1=accepted(OPC_SL_RD_DATA),​ 0x40=accepted blind(OPC_SL_RD_DATA),​ 0x7F=not implemented |
 +| **PCMD** | programmer command (0 will abort current operation) | 0,​WR,​BM,​TY1,​TY0,​OPS,​0,​0 |
 +|          | WR, Write/Read | 1=Write, 0=Read | 
 +|          | MD, Byte mode | 1=byte operation, 0=bit operation (if possible) | 
 +|          | OPS, Ops Mode | 1=Mainline, 0=PT | 
 +| **PSTAT²** | programmer error flags | 0,​0,​0,​0,​D3,​D2,​D1,​D0 |
 +|          | D3 | 1=User aborted | 
 +|          | D2 | 1=No read ack | 
 +|          | D1 | 1=No write ack | 
 +|          | D0 | 1=Programming track empty | 
 +| **HOPSA** | operations mode programming | 7 bit high addres, 0 if service mode (POM) | 
 +| **LOPSA** | operations mode programming | 7 bit low addres, 0 if service mode (POM) | 
 +| **CVH** | CV# | 0,​0,​CV9,​CV8,​0,​0D7,​CV7 | 
 +| **CVL** | CV# | 0,​CV6,​CV5,​CV4,​CV3,​CV2,​CV1,​CV0 | 
 +| **DATA7** | data | 0,​D6,​D5,​D4,​D3,​D2,​D1,​D0 | \\
 +¹)
 +Note that the <7F> code will occur in Operations Mode Read requests if the System is not configured for
 +and has no Advanced Acknowlegement detection installed.. Operations Mode requests can be made and
 +executed whilst a current Service Mode programming task is keeping the Programming track BUSY. If a
 +Programming request is rejected, delay and resend the complete request later. Some readback operations
 +can keep the Programming track busy for up to a minute. Multiple devices, throttles/​PC'​s etc, can share
 +and sequentially use the Programming track as long as they correctly interpret the response messages .
 +Any Slot RD from the master will also contain the Programmer Busy status in bit 3 of the <TRK> byte.\\
 + \\
 +²)
 +This <E7> response is issued whenever a Programming task is completed. It echos most of the request
 +information and returns the PSTAT status code to indicate how the task completed. If a READ was
 +requested <​DATA7>​ and <CVH> contain the returned data, if the PSTAT indicates a successful readback
 +(typically =0). Note that if a Paged Read fails to detect a successful Page write acknowledge when first
 +setting the Page register, the read will be aborted, showing no Write acknowledge flag D1=1\\
 + \\
 +
 + \\
 +
 +====Type codes====
 +^Byte Mode^ Ops Mode^ TY1^ TY0^ Meaning^
 +|       1 |     0 |   0 |  0 |  Paged mode byte Read/Write on Service Track |
 +|       1 |     0 |   0 |  0 |  Paged mode byte Read/Write on Service Track |
 +|       1 |     0 |   0 |  1 |  Direct mode byteRead/​Write on Service Track |
 +|       0 |     0 |   0 |  1 |  Direct mode bit Read/Write on Service Track |
 +|       x |     0 |   1 |  0 |  Physical Register byte Read/Write on Service Track |
 +|       x |     0 |   1 |  1 |  Service Track- reserved function |
 +|       1 |     1 |   0 |  0 |  Ops mode Byte program, no feedback |
 +|       1 |     1 |   0 |  1 |  Ops mode Byte program, feedback |
 +|       0 |     1 |   0 |  0 |  Ops mode Bit program, no feedback |
 +|       0 |     1 |   0 |  1 |  Ops mode Bit program, feedback |\\
 +
 +
 + \\
 + \\
 +===== Multi Sense =====
 +Power and transponding information is brought with the **''​OPC_MULTI_SENSE''​** opcode.\\ ​
 +===Power===
 +^ Variable ^ Value ^
 +| ARG1 | ? |
 +| ARG2 | ? |
 +| ARG3 | ? |
 +| ARG4 | ? |
 +
 + \\
 +===Transponding===
 +^ Variable ^ Value ^
 +| ARG1 | type, present/​absent,​ and high part board address |
 +| ARG2 | low part board address and Zone A to H in the lower 4 bits |
 +| ARG3 | high part of transponding mobile decoder address |
 +| ARG4 | low part of transponding mobile decoder address |
 +
 + \\
 +
 +===== Functions 9-12 =====
 +| Digitrax || Uhlenbrock ||
 +^ Variable ^ Value ^ Variable ^ Value ^ 
 +| OPC | OPC_IMM_PACKET | OPC | OPC_UHLI_FUN |
 +| REPS | 0x24 for short and 0x34 for long address| Arg1 | 0x20 |
 +| DHI  | 0x02 or 0x04 + high bits of address and functions | Arg2 | Slot# |
 +| IM1  | long address Lo | Arg3 | 0x07  |
 +| IM2  | long address Hi | Arg4 | f9=0x10, f10=0x20, f11=0x40 |
 +| IM3  | 0x20 + function bits & 0x7f |
 +| IM4  | 0x00 |
 +| IM5  | 0x00 |
 +| IM1  | short address |
 +| IM2  | 0x20 + function bits & 0x7f |
 +| IM3  | 0x00 |
 +| IM4  | 0x00 |
 +| IM5  | 0x00 |
 +
 +
 + \\
 +
 +===== Functions 13-20 =====
 +| Digitrax || Uhlenbrock ||
 +^ Variable ^ Value ^ Variable ^ Value ^ 
 +| OPC | OPC_IMM_PACKET | OPC | OPC_UHLI_FUN |
 +| REPS | 0x34 for short and 0x44 for long address| Arg1 | 0x20 |
 +| DHI  | 0x02 or 0x04 + high bits of address and functions | Arg2 | Slot# |
 +| IM1  | long address Lo | Arg3 | 0x05=f12+f20+f28, ​ 0x08=f13-f19 ​ |
 +| IM2  | long address Hi | Arg4 |  f12=0x10, f20=0x20, f28=0x40, f13=0x01...f19=0x40 |
 +| IM3  | 0x5E |
 +| IM4  | function bits & 0x7f |
 +| IM5  | 0x00 |
 +| IM1  | short address |
 +| IM2  | 0x5E |
 +| IM3  | function bits & 0x7f |
 +| IM4  | 0x00 |
 +| IM5  | 0x00 |
 +
 +
 + \\
 +
 +===== Functions 21-28 =====
 +| Digitrax || Uhlenbrock ||
 +^ Variable ^ Value ^ Variable ^ Value ^ 
 +| OPC | OPC_IMM_PACKET | OPC | OPC_UHLI_FUN |
 +| REPS | 0x34 for short and 0x44 for long address| Arg1 | 0x20 |
 +| DHI  | 0x06 + high bits of address and functions | Arg2 | Slot# |
 +| IM1  | long address Lo | Arg3 | 0x09 |
 +| IM2  | long address Hi | Arg4 | f21=0x01...f27=0x40 |
 +| IM3  | 0x5F |
 +| IM4  | function bits & 0x7f |
 +| IM5  | 0x00 |
 +| IM1  | short address |
 +| IM2  | 0x5F |
 +| IM3  | function bits & 0x7f |
 +| IM4  | 0x00 |
 +| IM5  | 0x00 |
 +
 +
 +
 +
 + \\
 +
 +===== Fast Clock =====
 + \\
 +The system FAST clock and parameters are implemented in Slot#123 <​7B>​.\\
 +Use <EF> to write new clock information,​ Slot read of 0x7B,<​BB><​7B>​..,​ will return current System
 +clock information,​ and other throttles will update to this SYNC. Note that all attached display devices
 +keep a current clock calculation based on this SYNC read value, i.e. devices MUST not continuously poll
 +the clock SLOT to generate time, but use this merely to restore SYNC and follow current RATE etc. This
 +clock slot is typically "​pinged"​ or read SYNC'd every 70 to 100 seconds , by a single user, so all attached
 +devices can synchronise any phase drifts. Upon seeing a SYNC read, all devices should reset their local
 +sub-minute phase counter and invalidate the SYNC update ping generator.
 +
 +==== Parameters ====
 +
 +^  Name  ^  Description ​ ^  Bits/​Range ​ ^
 +| **CLK_RATE** | Clock rate | 0=Freeze clock, 1=normal 1:1 rate, 10=10:1 etc, max VALUE is 7F/128 to 1 |
 +| **FRAC_MINSH/​L** | FRAC mins hi/lo are a sub-minute counter , depending on the CLOCK generator. Not for ext. usage. | This counter is reset when valid <​E6><​7B>​ SYNC msg seen. |
 +| **256-MINS_60** | This is FAST clock MINUTES subtracted from 256. | Modulo 0-59 |
 +| **256-HRS_24** | This is FAST clock HOURS subtracted from 256. | Modulo 0-23 |
 +| **DAYS** | number of 24 Hr clock rolls, positive count | |
 +| **CLK_CNTRL** | Clock Control Byte | D6- 1=This is valid Clock information,​ 0=ignore this <​E6><​7B>,​ SYNC reply |
 +| **ID1/2** | This is device ID last setting the clock. | <​00><​00>​ shows no set has happened, <​7F><​7x>​ are reserved for PC access |
 +
 +
 + \\
 +
 +=====Stationary Broadcast Command=====
 +Note that a 3 byte DCC track packet configured as:\\
 +<​code>​
 +<​sync>​ ,<​1011-1111>,<​1000-D c b a > <ecb> </​code>​ is a DCC Broadcast Address to Stationary decoders.
 +Broadcast LocoNet Switch adr is then <​code><​SW2>​=<​0,​0,​a,​D-1,​1,​1,​1>,​ <​SW1>​=<​0,​1,​1,​1-1,​0,​c,​b></​code>​
 +
 + \\
 +
 +=====Stationary Interrogate Command=====
 +The DCC packet <​code><​sync>,<​1011-1111>,<​1100-D c b a> <​ecb></​code>​is an Interrogation for all DS54'​s. This
 +causes a 2 LocoNet <B1> messages encoding both Output state and Input state, for each sensor adr a/b/c
 +encodes.
 +Interrogate LocoNet Switch adr is <​code><​SW2>​=<​0,​0,​a,​1-0,​1,​1,​1>,​ <​SW1>​= <​0,​1,​1,​1-1,​0,​c,​b></​code>​
 +This is generated by DCS100 at power ON, and scans all 8 inputs of all DS54'​s.
loconet/lnpe-parms-en.txt · Last modified: 2018/11/12 08:56 (external edit)