User Tools

Site Tools


mbus:cs3-en

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
mbus:cs3-en [2020/12/02 18:50] – [CS2 / CS3] besrambus:cs3-en [2022/05/01 10:40] (current) – [Switch/Output] rjversluis
Line 2: Line 2:
 [[:english#command_stations|{{  :interface.png}}]][[:english|{{  :rocrail-logo-35.png}}]] [[:english#command_stations|{{  :interface.png}}]][[:english|{{  :rocrail-logo-35.png}}]]
 [[:english|Content]] -> **[[:english#command_stations|Command Stations]]** -> Märklin [[:english|Content]] -> **[[:english#command_stations|Command Stations]]** -> Märklin
-  * **[[:mbus:mbus-en|MBUS]]**+  * **[[:mbus:mbus2-en|MBUS]]**
     * [[:mbus:functions-en|Function Codes]] | **[[:mbus:cs3-en|CS2/CS3]]** |  [[:mbus:mbus-en|TrackBox(GleisBox)]] | [[:mbus:channels-en|Channels]]     * [[:mbus:functions-en|Function Codes]] | **[[:mbus:cs3-en|CS2/CS3]]** |  [[:mbus:mbus-en|TrackBox(GleisBox)]] | [[:mbus:channels-en|Channels]]
 {{:mbus:cs3plus.png?200}}\\ {{:mbus:cs3plus.png?200}}\\
Line 16: Line 16:
 ====Communication Type==== ====Communication Type====
 The preferred way to communicate with the CS3 is by using the TCP type.\\ The preferred way to communicate with the CS3 is by using the TCP type.\\
 +The CS3 TCP port is factory set to 15731, the second port is not utilized.\\
 +Classic CS2 UDP communication uses two port numbers, sending (Tx) and receiving (Rx). \\
 +If the port entry is set to zero, it is automatically replaced with the default values, 15731 and 15730. \\
 {{:mbus:mbus-interface-en.png}}\\ {{:mbus:mbus-interface-en.png}}\\
-The CS3 TCP port is factory set to 15731.\\+
 ====Overview==== ====Overview====
 If all went well, the CS3 is listed in the CBUS/MBUS dialog:\\ If all went well, the CS3 is listed in the CBUS/MBUS dialog:\\
Line 42: Line 45:
  \\  \\
 ====LinkS88==== ====LinkS88====
-|  //Starting with revision 15.073, this setup is no longer needed; Its detected automatically.//  |\\ +|  //This setup is no longer needed; Its detected automatically.//  |\\ 
-This setup is needed to be able to detect the sensor state at start up.\\+<del>This setup is needed to be able to detect the sensor state at start up.</del>
 |{{:mbus:links88-setup-de.png?0x240}}|{{:mbus:mbus-sensors-en.png?0x240}}|\\ |{{:mbus:links88-setup-de.png?0x240}}|{{:mbus:mbus-sensors-en.png?0x240}}|\\
 An entry in the list is needed for each connected LinkS88 device.\\ An entry in the list is needed for each connected LinkS88 device.\\
Line 70: Line 73:
 =====Addressing===== =====Addressing=====
 ====Switch/Output==== ====Switch/Output====
-An example for the real switch address **11**:+An example for the real switch address **12**:
 |< >| |< >|
-^ Type ^ Address ^ Port ^ Calculation ^ Remark ^ +^ Type ^ Address ^ Port ^ Remark ^ 
-^ MADA |   3 |   4 |  (3-1)*4+(4-1)=11 | +^ MADA |   3 |   4 | Not supported! 
-^ PADA |   0 |  12 |  12-1=11 | Recommended: Same scheme as the display address in the CS2/CS3 GUI. | +^ PADA |   0 |  12 | Same scheme as the display address in the CS2/CS3 GUI. | 
-^ FADA |   - |  - | Not supported! |+^ FADA |   - |   - | Not supported! |
  
  \\  \\
Line 100: Line 103:
  
  \\  \\
-===== Connecting a CS2 / CS3 with Rocrail step-by-step ===== 
  
-  - Select in the toolbar: File 
-  - Select in the menu: Open Workspace / Recent Workspace 
-  - Open the desired file 
-  - Select in the toolbar: File 
-  - Choose in the menu: Rocrail Properties. A new window will open 
-  - Select the tab: Controller 
-  - Click on the vcs-1 (virtual controller), which is in the window 
-  - Click on: delete 
-  - Click on dropdown: new 
-  - Select: MBUS and click on it 
-  - Click on: add, in the window appears: NEW (the selected MBUS) 
-  - Click on: NEW in the window 
-  - Click on: Properties 
-  - Click on: Interface ID and change the name NEW to a name of personal choice, e.g. ''CS3'' or ''CS-3'' 
-  - Check: TCP, enter the IP address at Hostname and after the colon 15731 
-  - Click on: OK 
-  - Close Rocrail (in Win: Ctrl-D, in MacOS: Strg-D) 
-  - Restart Rocrail, perform Steps 1, 2 en 3 again 
-  - Start the CS3 and put it on stop 
-  - Click on the lightbulb icon in the toolbar: the CS3 now switches on 
-  - Click on the lightbulb icon in the toolbar: Turn off the power, the CS3 now switches off 
-  - Select in the toolbar: Programming 
-  - Click in the menu on: CANBUS, a window will open and the window should contain the CS3 and the GFP3 
-\\ \\ 
mbus/cs3-en.1606931439.txt.gz · Last modified: 2020/12/02 18:50 by besra