mbus:cs3-en
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
mbus:cs3-en [2020/12/02 18:50] – [CS2 / CS3] besra | mbus:cs3-en [2022/05/01 10:40] (current) – [Switch/Output] rjversluis | ||
---|---|---|---|
Line 2: | Line 2: | ||
[[: | [[: | ||
[[: | [[: | ||
- | * **[[:mbus:mbus-en|MBUS]]** | + | * **[[:mbus:mbus2-en|MBUS]]** |
* [[: | * [[: | ||
{{: | {{: | ||
Line 16: | Line 16: | ||
====Communication Type==== | ====Communication Type==== | ||
The preferred way to communicate with the CS3 is by using the TCP type.\\ | The preferred way to communicate with the CS3 is by using the TCP type.\\ | ||
+ | The CS3 TCP port is factory set to 15731, the second port is not utilized.\\ | ||
+ | Classic CS2 UDP communication uses two port numbers, sending (Tx) and receiving (Rx). \\ | ||
+ | If the port entry is set to zero, it is automatically replaced with the default values, 15731 and 15730. \\ | ||
{{: | {{: | ||
- | The CS3 TCP port is factory set to 15731.\\ | + | |
====Overview==== | ====Overview==== | ||
If all went well, the CS3 is listed in the CBUS/MBUS dialog:\\ | If all went well, the CS3 is listed in the CBUS/MBUS dialog:\\ | ||
Line 42: | Line 45: | ||
\\ | \\ | ||
====LinkS88==== | ====LinkS88==== | ||
- | | //Starting with revision 15.073, this setup is no longer needed; Its detected automatically.// | + | | //This setup is no longer needed; Its detected automatically.// |
- | This setup is needed to be able to detect the sensor state at start up.\\ | + | <del>This setup is needed to be able to detect the sensor state at start up.</ |
|{{: | |{{: | ||
An entry in the list is needed for each connected LinkS88 device.\\ | An entry in the list is needed for each connected LinkS88 device.\\ | ||
Line 70: | Line 73: | ||
=====Addressing===== | =====Addressing===== | ||
====Switch/ | ====Switch/ | ||
- | An example for the real switch address **11**: | + | An example for the real switch address **12**: |
|< >| | |< >| | ||
- | ^ Type ^ Address ^ Port ^ Calculation | + | ^ Type ^ Address ^ Port ^ Remark ^ |
- | ^ MADA | 3 | 4 | | + | ^ MADA | 3 | 4 | Not supported! |
- | ^ PADA | 0 | 12 | | + | ^ PADA | 0 | 12 | Same scheme as the display address in the CS2/CS3 GUI. | |
- | ^ FADA | - | - | Not supported! | + | ^ FADA | - | |
\\ | \\ | ||
Line 100: | Line 103: | ||
\\ | \\ | ||
- | ===== Connecting a CS2 / CS3 with Rocrail step-by-step ===== | ||
- | - Select in the toolbar: File | ||
- | - Select in the menu: Open Workspace / Recent Workspace | ||
- | - Open the desired file | ||
- | - Select in the toolbar: File | ||
- | - Choose in the menu: Rocrail Properties. A new window will open | ||
- | - Select the tab: Controller | ||
- | - Click on the vcs-1 (virtual controller), | ||
- | - Click on: delete | ||
- | - Click on dropdown: new | ||
- | - Select: MBUS and click on it | ||
- | - Click on: add, in the window appears: NEW (the selected MBUS) | ||
- | - Click on: NEW in the window | ||
- | - Click on: Properties | ||
- | - Click on: Interface ID and change the name NEW to a name of personal choice, e.g. '' | ||
- | - Check: TCP, enter the IP address at Hostname and after the colon 15731 | ||
- | - Click on: OK | ||
- | - Close Rocrail (in Win: Ctrl-D, in MacOS: Strg-D) | ||
- | - Restart Rocrail, perform Steps 1, 2 en 3 again | ||
- | - Start the CS3 and put it on stop | ||
- | - Click on the lightbulb icon in the toolbar: the CS3 now switches on | ||
- | - Click on the lightbulb icon in the toolbar: Turn off the power, the CS3 now switches off | ||
- | - Select in the toolbar: Programming | ||
- | - Click in the menu on: CANBUS, a window will open and the window should contain the CS3 and the GFP3 | ||
- | \\ \\ |
mbus/cs3-en.1606931439.txt.gz · Last modified: 2020/12/02 18:50 by besra