 +======Marklin 6050/6051======
 +[[:english#command_stations|{{  :interface.png}}]][[:english|{{  :rocrail-logo-35.png}}]]
 +
 +[[english|Content]] -> [[english#command_stations|Command Stations]] ->   **Marklin 6050/6051** 
 +   
 +
 +// \\ // \\
 +|  Deprecated and no longer supported!  |\\
 +
 +Because of the lack of a direction bit in this ancient protocol some features will probably not work in auto mode.\\
 + 
 +=====Cable configuration=====
 +Interface 6050/6051 to RS232
 +| **DIN-6** | **D-SUB-9** | Label |
 +| 1 | 3 | Rx |
 +| 4 | 2 | Tx |
 +| 5 | 8 | CTS |
 +| 3 | 5 | Ground |
 +
 +**Bridge** on D-SUB-9 side pin: **4 - 6 - 1**
 +
 +
 +=====Settings=====
 +General Command Station setup dialog:\\
 +{{:p50-setup-en.png}}\\
 +
 +====Line settings====
 +===Baudrate===
 +2400\\
 +===Hardware Flow===
 +CTS\\
 +
 +====Sensors====
 +===Number===
 +Number of s88 units.
 +
 +====Version====
 +|< >|
 +^ Version ^ Command sleep ^ comment ^
 +|  0 |  0ms | | 
 +|  1 |  10ms | |
 +|  2 |  50ms |otherwise cts timeout|
 +With version 2, the direction change will skip the preceding speed zero command.\\
 +
 +====Switch time====
 +Time in ms to wait after the last switch command before a switch off command is send to prevent coil damaged.\\
 +Use 1000 (if old and slow magnetic objects)
 +
 + \\
 +=====Interface 6023=====
 +The 6023 interface must be switched to binary mode for using this protocol; Read section 6 on how to switch to binary mode.\\
 +  * {{:marklin:ma6023.pdf}}
 +
 + \\
  
6050-en.txt · Last modified: 2021/05/07 21:10 by 127.0.0.1