loconet:transponding-en
no way to compare when less than two revisions
Differences
This shows you the differences between two versions of the page.
— | loconet:transponding-en [2018/11/12 08:56] (current) – created - external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== Transponding ====== | ||
+ | [[: | ||
+ | [[: | ||
+ | * [[: | ||
+ | |||
+ | // \\ // \\ | ||
+ | ===== Transponding & Rocrail ===== | ||
+ | Transponding can be ordered to the same category as Lissy and RailCom but uses another technique.\\ | ||
+ | \\ | ||
+ | With the basic transponding decoders the following info is received by Rocrail: | ||
+ | * decoder address | ||
+ | * BDL168 board number | ||
+ | * zone A, B, C, D, E, F, G or H | ||
+ | \\ | ||
+ | More advanced transponding decoders can supply also: | ||
+ | * operations mode readback of decoder CVs | ||
+ | * information about the speed and other status data | ||
+ | * surround sound system support | ||
+ | \\ | ||
+ | |||
+ | \\ | ||
+ | ===== Addressing ===== | ||
+ | To avoid conflicts with the current sense addressing bus 2 is used for the transponder receivers.\\ | ||
+ | So if the board address is set to **1** the first transponder receiver will report in Rocrail with address **2-1**, and the first sensor with address **0-1**. (bus-address)\\ | ||
+ | |||
+ | The BDL168 transponder addresses increment by 2, not 1. This means with board address 2 that Zone A is 1, Zone B is 3, etc. See this table:\\ | ||
+ | |||
+ | \\ | ||
+ | |||
+ | ^ Board 1 RX's ^^^ | ||
+ | ^ Zone ^ Bus ^ Address ^ | ||
+ | | A | 1 | 1 | | ||
+ | | B | 1 | 3 | | ||
+ | | C | 1 | 5 | | ||
+ | | D | 1 | 7 | | ||
+ | | E | 1 | 9 | | ||
+ | | F | 1 | 11 | | ||
+ | | G | 1 | 13 | | ||
+ | | H | 1 | 15 | \\ | ||
+ | |||
+ | |||
+ | \\ | ||
+ | =====Recommended settings===== | ||
+ | ==== BDL168 ==== | ||
+ | | OPSW9 | Closed (No message sent if un-powered) | | ||
+ | | OPSW36 | Closed (Ignore GPON) | | ||
+ | | OPSW37 | Closed (Long delay for sensors) | | ||
+ | | OPSW38 | Closed (Extra long delay for sensors) | | ||
+ | | OPSW39 | Closed (Verbose mode enabled) | | ||
+ | | OPSW42 | Closed (Respond also to first interrogate command) | | ||
+ | | OPSW43 | Thrown (Filter for transponding enabled) | | ||
+ | | OPSW44 | Closed (Extra filter for transponding) | | ||
+ | | OPSW45 | Closed (Don't send transponding messages at GPOFF) | | ||
+ | |||
+ | \\ | ||
+ | ===== Test Setup ===== | ||
+ | {{: | ||
+ | |||
+ | |||
+ | \\ | ||
+ | |||
+ | ===== Links ===== | ||
+ | * [[http:// | ||
+ | * [[http:// | ||
+ | * [[http:// | ||
+ | |||
loconet/transponding-en.txt · Last modified: 2018/11/12 08:56 by 127.0.0.1