 +====== Transponding ======
 +[[:english#interfaces|{{  :interface.png}}]][[:english|{{  :rocrail-logo-35.png}}]] 
 +[[:english|Content]] -> [[:english#command_stations|Command Stations]] -> **[[:loconet-en| Digitrax LocoNet]]** 
 +   * [[:loconet-cs-en|Command Stations]] | [[:loconet-interfaces-en|Interfaces]] | [[:lnfc-en|Fast Clock]] | [[:loconet-dev-en|Throttles]] | [[:locont-wi-en|Wiring]]
 +
 +// \\ // \\
 +===== Transponding & Rocrail =====
 +Transponding can be ordered to the same category as Lissy and RailCom but uses another technique.\\
 + \\
 +With the basic transponding decoders the following info is received by Rocrail:
 +  * decoder address
 +  * BDL168 board number
 +  * zone A, B, C, D, E, F, G or H
 + \\
 +More advanced transponding decoders can supply also:
 +  * operations mode readback of decoder CVs
 +  * information about the speed and other status data
 +  * surround sound system support
 + \\
 +
 + \\
 +===== Addressing =====
 +To avoid conflicts with the current sense addressing bus 2 is used for the transponder receivers.\\
 +So if the board address is set to **1** the first transponder receiver will report in Rocrail with address **2-1**, and the first sensor with address **0-1**. (bus-address)\\
 +
 +The BDL168 transponder addresses increment by 2, not 1.  This means with board address 2 that Zone A is 1, Zone B is 3, etc.  See this table:\\
 +
 + \\
 +
 +^ Board 1 RX's ^^^
 +^ Zone ^ Bus ^ Address ^
 +| A | 1 | 1 |
 +| B | 1 | 3 |
 +| C | 1 | 5 |
 +| D | 1 | 7 |
 +| E | 1 | 9 |
 +| F | 1 | 11 |
 +| G | 1 | 13 |
 +| H | 1 | 15 | \\
 +
 +
 + \\
 +=====Recommended settings=====
 +==== BDL168 ====
 +| OPSW9   | Closed (No message sent if un-powered) |
 +| OPSW36 | Closed (Ignore GPON) |
 +| OPSW37 | Closed (Long delay for sensors) | 
 +| OPSW38 | Closed (Extra long delay for sensors) | 
 +| OPSW39 | Closed (Verbose mode enabled) |
 +| OPSW42 | Closed (Respond also to first interrogate command) |
 +| OPSW43 | Thrown (Filter for transponding enabled) |
 +| OPSW44 | Closed (Extra filter for transponding) |
 +| OPSW45 | Closed (Don't send transponding messages at GPOFF) |
 +
 + \\
 +===== Test Setup =====
 +{{:loconet:bdl168-rx4-setup-01.jpg?400}}\\
 +
 +
 + \\
 +
 +===== Links =====
 +  * [[http://www.digitrax.com/menu_transponding.php|Digitrax]]
 +  * [[http://www.dccwiki.com/Transponding|DCC Wiki]]
 +  * [[http://en.wikipedia.org/wiki/Transponder|Wikipedia]]
 +
  
loconet/transponding-en.txt · Last modified: 2018/11/12 08:56 by 127.0.0.1