Action disabled: source
                bidib-examples-en
                Table of Contents
BiDiB Setup Examples
Switch setup
Example Servo
Bus → Decimal Unique-ID

This example shows how to address servo port 1 on a LightControl. The accessory flag must be unchecked.
The decimal Unique-ID is set in the Bus field which can be done with D&D.
Parameter/Value
5698+
Optional the servo position can be specified:
- Parameter → straight position
- Value → thrown position
 
Example Dual Coil
- Disable "Single Gate"
Address + 1 is used for controlling the second coil of the switch motor. (turnout)
 
DCC Accessory
| Field | Value | Remark | 
|---|---|---|
| Bus | Decimal Unique-ID | Default GBMBoost Master if left empty. If MultiMaus1) accessory commands should also processed the Bus value must be set to the UID of the GBMBoost Master. | 
| Protocol | NMRA-DCC | |
| Address | 1…65536 | Is mapped to NMRA 0…65535 | 
| Port | Not used | |
| Gate | 0, 1 | Only for single coil switch motors or Outputs | 
| Type | Accessory | 
 
Signal setup
Example MoBaLiSt
Bus → Decimal Unique-ID

This example shows how to address lights port 1…4 on a MoBaLiSt. The accessory flag must be unchecked.
The decimal Unique-ID is set in the Bus field which can be done with D&D.
 
Sensor setup
Bus → Decimal Unique-ID
Address → Port number + 1
Server trace
MSG_BM_CONFIDENCE: uid=00010068 path=0.0.0.0 void=0 freeze=0 signal=0 sensor bus=00010068 addr=5 state=occ ident=1057 type=loco-addr-fwd
| Sensor message | |
|---|---|
| bus | Unique-ID (hex value) | 
| addr | local module port address | 
| state | occupancy: free/occ | 
| ident | Railcom loco address | 
See http://www.bidib.org/protokoll/bidib_occ.html for more information about confidence.
 
1) 
Or any other Xpressnet throttle.
bidib-examples-en.txt · Last modified: 2020/12/03 22:04 by 127.0.0.1
                
                