Liste d'adresse LocoIO

SommaireRocviewProgrammationDécodeurs Stationnaires



Obtenir une vue d'ensemble des modules LocoIO qui sont connectés au LocoNet.


Query

Le bouton Query(Requète) diffuse une obtention SV 0 à l'adresse 0/1 et tous les modules basés sur LocoIO connectés répondront et seront listés.

Avec un double clic l'adresse du module sélectionné est configuré dans l'onglet Général et est utilisé pour un traitement ultérieur comme Easy Setup.


Report

Avant de rapporter le bouton Query devra être appuyé pour remplir la liste.
L'option de rapport requiert le nom d'un fichier qui doit être spécifié par une fenêtre de dialogue. Le format du fichier est du type CSV et peut être lu et manipulé par la plupart des programmes tableur.
Tous les modules LocoIO listés sont ultérieurement sélectionnés, lecture et port par port signalé. L'identifiant devra être également rapporté si un objet Rocrail est lié à l'adresse du port.

Exemple

"low-addr.","sub-addr.","port","pin","I/O","ID"
"4","1","401","1","input","not used"
"4","1","402","2","input","not used"
"4","1","403","3","input","4f3"
"4","1","404","4","input","4f1"
"4","1","405","5","input","not used"
"4","1","406","6","input","not used"
"4","1","407","7","input","4f2"
"4","1","408","8","input","4f4"
"4","1","409","9","output","not used"
"4","1","410","10","output","not used"
"4","1","411","11","output","not used"
"4","1","412","12","output","not used"
"4","1","413","13","output","not used"
"4","1","414","14","output","not used"
"4","1","415","15","output","not used"
"4","1","416","16","output","not used"
"6","2","617","1","input","not used"
"6","2","618","2","input","not used"
"6","2","619","3","input","6f16"
"6","2","620","4","input","6f7"
"6","2","621","5","input","6f2"
"6","2","622","6","input","6f8"
"6","2","623","7","input","6f3"
"6","2","624","8","input","6f17"
"6","2","625","9","output","not used"
"6","2","626","10","output","not used"
"6","2","627","11","output","not used"
"6","2","628","12","output","not used"
"6","2","625","13","input","6t5"
"6","2","626","14","input","m6t8"
"6","2","627","15","input","not used"
"6","2","628","16","input","6t4"
"3","1","301","1","input","3f3"
"3","1","302","2","input","3f1"
"3","1","303","3","input","3f2"
"3","1","304","4","input","not used"
"3","1","305","5","input","3f5"
"3","1","306","6","input","3f6"
"3","1","307","7","input","not used"
"3","1","308","8","input","3f4"
"3","1","309","9","output","not used"
"3","1","310","10","output","not used"
"3","1","311","11","output","not used"
"3","1","312","12","output","not used"
"3","1","313","13","input","3t1"
"3","1","314","14","input","3t2"
"3","1","315","15","input","not used"
"3","1","316","16","input","not used"
"2","1","201","1","input","2f13"
"2","1","202","2","input","2f6"
"2","1","203","3","input","2f7"
"2","1","204","4","input","2f12"
"2","1","205","5","input","not used"
"2","1","206","6","input","2f8"
"2","1","207","7","input","2f11"
"2","1","208","8","input","2f10"
"2","1","209","9","output","2t3"
"2","1","210","10","output","not used"
"2","1","211","11","output","2t2"
"2","1","212","12","output","2t1"